The Red Line XDI sensor uses proven non-dispersive single beam dual-wave length infrared principles to detect and monitor the presence of gases. This non-poisoning sensing technique relies on the target gas having a unique well-defined absorption signature. This is used to identify the presence of the target gas and is highly specific. Using a suitable infrared source, an analysis of the optical absorption through the gas allows the concentration of the target gas to be determined.
All sensor driving is internal to the transmitter and full fault monitoring of the sensor and transmitter is continuous. The sensor signal is used to provide a linear output in voltage and 4-20mA format, calibration is by means of 4 and 20mA span potentiometers with the signal being internally linearised without the need for user adjustments.
| This information relates to the device operating continuously. The device may be calibrated for other gases. | |
| Hydrocarbon Sensor | |
| Operation continuous diffusion | NDIR (duel wave-length) |
| Measuring Range – Standard | 0-100% LEL |
| Others available | |
| Accuracy | ± 5% F.S.D |
| Warm up time to zero | < 20 seconds |
| Response time to target gas T90 | < 35 seconds |
| Long term zero drift | ± 5% F.S.D |
| Internal indicators are included for designating the transmitter status. | |
| These include:- | Device Active |
| Indication of sensor source pulsing | |
| Indication of the calibration mode | |
| Fault diagnostics | |
|
The 4~20mA output provides a fault indication by reducing the output to below 3mA, with the recovery from |
|
| Input voltage – 3 wire device (polarity protected) | 12 to 35V DC – 24v DC nominal |
| Output | 4~20mA (link selectable as sink or source) |
| Voltage output 1~5V, maximum current draw | 5mA |
| Maximum current consumption | 130mA |
| Resolution | 0.15% of span |
| Maximum loop resistance in source mode | 250R |
| Output resolution | 0.02mA |
| Maximum offset drift | ± 20uA |
| Over-range output | 21.3mA (typical) |
| Fail signal | 4-20mA reduced to 3mA |
| Fail indicator | Open collector output to 0V |
| Certification | ATEX – EExd IIC T6 112GD |
| F1 Sensor – SCS Cert No 03ATEX1176X | |
| ATEX – XDI Enclosure FTZU– Cert No 06ATEX0296X | |
| Replaceable plug in sensor | In-situe |
| Sensor accessory mounting thread | 33mm ø 1.25 pitch – 6 full threads |
| Enclosure – Type XDI | Aluminium alloy - optional stainless steel |
| Gas Sensor – Type F1 | Stainless steel – 316 S16 |
| Weight | 3.95Kg |
| Cable Entry | One – 20 mm 1.5 pitch |
| Options 25 mm - 3/4 NPT | |
| Mounting Detail | Two M5 (126 mm CRS) |
| Approximate dimensions-terminal enclosure | 126 mm dia. 83 mm deep |
| On Board Indicators: - | |
| Green LED | System healthy |
| Three red LED’s | System diagnostics |
|
|
IP53 + Water Shield IP65 Operating Conditions 0 ~100% RH (non-condensing) -10 ~ +50ºC Storage Conditions 0~100% RH (non-condensing) -20 ~ +60ºC Accessories:- 1 - 003-010 Collector Cone + universal fitting 2 – 003-020 Test Gas Applicator Spray Deflector 3 – 008-311 Flow Block 4 – 003-035 Water Shield 5 – 003-090 Duct Mount Kit |
DELIVERY OPTIONS:
UK Orders
There are various shipping options that you can select in the checkout area.
Standard Delivery FREE - Standard delivery items will be delivered via the Royal Mail in the UK.
Items generally take between 2-4 working days to arrive (Mon-Fri). If you place your order after 1PM Mon-Fri then please allow 2-4 working days from the following day.
Occasionally due to reasons out of our control such as bad shipping conditions in the Channel Islands items may take a day or two longer than usual to arrive.
Recorded Delivery £0.75 - Recorded delivery items will be delivered via the Royal Mail in the UK and will require a signature upon arrival.
Items generally take between 2-4 working days to arrive (Mon-Fri). If you place your order after 1PM Mon-Fri then please allow 2-4 working days from the following day.
Occasionally due to reasons out of our control such as bad shipping conditions in the Channel Islands items may take a day or two longer than usual to arrive.
All items are sent in protective jiffy bags and should reach you in an unopened and brand new condition.
International Orders
We accept orders from international customers as long as you are using either Visa or Mastercard as your payment method. We have two shipping options for International customers:
Standard Airmail Standard Airmail items will be delivered by your local postal service and should take between 3-7 days to reach the customer depending on the country where the order is being delivered. Standard Airmail does not provide a tracking number and is not insure for loss or damage. We cannot be held responsible for any International orders that go missing using standard Airmail.
We will not be held resonsible for any International orders that go missing in transit. There is always an added risk when sending items overseas. Unfortunately we cannot offer an insured service for International orders at present.
©2012 Frontline Safety. Web Design Company Adeo Group