Blackline Safety EXO 4-inlet Pump Module

PRODUCT CODE:
ACC-EXO-PUMP

The Blackline Safety EXO 4-Inlet Pump Module converts a diffusion EXO area monitor to pumped operation, with four sample inlets and remote sampling up to 30 metres. Ideal for confined space pre-entry checks, leak investigation and monitoring inaccessible locations.

The kit includes the pump module itself along with an enclosed cover and pump gas chamber

£2,019.60 inc VAT
£1,683.00
Loading...

Product description

The Blackline Safety EXO 4-Inlet Pump Module is an add-on accessory that converts a diffusion EXO area monitor into a pumped instrument, drawing sample gas actively rather than relying on ambient diffusion. This makes it suitable for pre-entry confined space checks, leak detection and monitoring in locations where the EXO itself cannot be placed.

The module provides four separate sample inlets and supports sample lengths of up to 30 metres (100 feet) when used with compatible tubing. It operates across the full EXO temperature range of -20°C to 50°C (-4°F to 122°F), maintaining the same environmental tolerance as the host instrument. A small number of reactive gas sensors, including chlorine (Cl2), chlorine dioxide (ClO2) and hydrogen cyanide (HCN), are not compatible with pumped operation and must remain in diffusion configuration.

The pump module is typically paired with a Blackline Safety EXO 8 Area Monitor and works alongside standard Blackline accessories including replacement pump cartridge particulate filters, and Tygon sampling tubing in 2, 10, 50 and 100 foot lengths, and Teflon lined sampling tubing in 2, 10 and 50 foot lengths.

Key Features

  • Converts a diffusion Blackline Safety EXO to pumped operation without replacing the unit
  • Four sample inlet channels for drawing gas from multiple points or a single remote location
  • Remote sample length up to 30 metres (100 ft) using compatible Tygon or Teflon-lined tubing
  • Operates across the full EXO temperature range of -20°C to 50°C
  • Compatible with Blackline Safety sample probes and pump cartridge particulate filters
Specification

Part Number

ACC-EXO-PUMP

Compatibility

Blackline Safety EXO Area Monitor (diffusion to pumped conversion)

Sample Inlet Channels

4

Sample Length

Up to 30 metres (100 ft)

Operating Temperature

-20°C to 50°C (-4°F to 122°F)

Sensor Exceptions

  • Chlorine (Cl2) - not compatible with pump module
  • Chlorine Dioxide (ClO2) - not compatible with pump module
  • Hydrogen Cyanide (HCN) - not compatible with pump module

Compatible Accessories

  • Sample Probe 12 inch (ACC-G7-PROBE-12)
  • Sample Probe 36 inch (ACC-G7-PROBE)