Drager Amine 0-100 ppm Sensor

PRODUCT CODE:
6809545
Drager Amine 0-100 ppm Sensor
£918.06 inc VAT
£765.05
Loading...

Product description

Drager Amine 0-100 ppm Sensor

This DragerSensor XS EC is for the detection of Amine gas.  This sensor is suitable for the X-am 7000 multi gas detector and can be used in industries such as foundries, refineries and power plants.

More information measuring ranges can be found below: 

  • 0 to 100 ppm CH3NH2 (methylamine)
  • 0 to 100 ppm (CH3)2NH (dimethylamine)
  • 0 to 100 ppm (CH3)3N (trimethylamine)
  • 0 to 100 ppm C2H5NH2 (ethylamine)
  • 0 to 100 ppm (C2H5)2NH (diethylamine)
  • 0 to 100 ppm (C2H5)3N (triethylamine)

 

 

Key Features

  • This is a plug and play sensor which can be easily replaced
  • Features a 1 year guarantee
  • Can be used to detect different amines
  • Other amines are automatically calibrated using ammonia test gas
Specification

Detection Limit

2 ppm

Resolution

1 ppm

Response Time

≤ 30 seconds at 20 °C or 68 °F (T50)

Measurement accuracy

Zero Point:  ≤ ± 2 ppm
Sensitivity:  ≤ ± 3% of measured value

Long-term drift, at 20°C (68°F)

Zero Point:  ≤ ± 2 ppm/month
Sensitivity:  ≤ ± 3% of measured value/month

Warm-up time:

≤ 12 hours

Ambient conditions

Temperature: (–40 to 50)°C (–40 to 122)°F
Humidity: (10 to 90)% RH
Pressure: (700 to 1,300) hPa

Influence of Temperature

Zero Point:  ≤ ± 5 ppm
Sensitivity:  ≤ ± 5% of measured value 

Influence of Humidity

Zero Point:  ≤ ± 0.1 ppm/% RH
Sensitivity:  ≤ ± 0.2% of measured value/% RH

Test Gas

approx. 50 to 100 ppm NH3 or one of the other target gases (MA, DMA, TMA, EA, DEA, TEA)