Drager Short-Term Detection Tubes - Chlorobenzene 5/a (Pack of 5)

PRODUCT CODE:
6728761

These tubes are designed for spot-measurements and must be used with the Drager Accuro Gas Detection Pump. Buy now from Frontline Safety.

Loading...
£100.09 inc VAT
£83.41

Product description

Drager Detection Tubes - Chlorobenzene 5/a (Pack of 5)

Drager gas detection tubes are a cost-effective way of measuring a large variety of different gases including Chlorobenzene (5/a).  These have a measurement range of 1 to 15 ppm and come in a pack of 5 tubes.

They can also detect a range of other substances including Benzyl Chloride and o,m,p-Dichlorobenzene.  The shelf life on these tubes is 2 years.

Buy the Drager Accuro Gas Detection Pump by clicking here .  This is required for the use of short-term gas detection tube.

Key Features

  • Designed for short-term, on-the-spot measurement
  • Can take between 10 seconds to 15 minutes to gather a reading
  • Applications may include concentration fluctuations in the workplace, measurement of contaminants in breathing zone, and confined spaces
  • Can be used as pre-entry checks
Specification
Application Range  
Standard Measuring Range: 5 to 200 ppm
Number of Strokes n: 10
Time for Measurement: approx. 3 min
Standard Deviation: ± 10 to 15 %
Color Change: blue --> yellowish-grey
   
Ambient Operating Conditions  
Temperature: 10 to 40 °C
Absolute Humidity: 3 to 15 mg H2O / L
   
Reaction Principle  
a) C6H5Cl + CrVI --> HCl
b) HCl + bromophenol blue --> yellow reaction product
 
Cross Sensitivity
Other chlorinated hydrocarbons are indicated as well, but with different sensitivities. Methylene chloride does not affect the indication. Chlorine and hydrogen chloride in the TLV range are absorbed in the pre-layer, but in such concentrations do not affect the indication.
Reviews