Drager Short Term Detection Tubes - Ethylene 0.1/a (Pack of 5)

PRODUCT CODE:
8101331

These tubes are designed for spot-measurements and must be used with the Drager Accuro Gas Detection Pump. Buy now from Frontline Safety.

£112.60 inc VAT
£93.83
Loading...

Product description

Drager Detection Tubes - Ethylene 0.1/a (Pack of 5)

This type of short-term gas detection tube is for Ethylene (0.1/a).  The tube has a measurement range of 0.1 to 5 ppm and come in a pack of 5 tubes.

The ethylene tubes have a shelf life of 2 years.

The Drager Gas Detection Pump (Accuro) is compatible with the short-term gas detection tubes.  You can purchase this product by clicking here .

Key Features

  • Reach difficult measurement areas with the tubes, pump and accessories
  • Carry out measurements on the spot
  • Measurement results may take between 10 seconds and 15 minutes depending on the type of tube used
  • Applications for use include variations in concentrations in the workplace, contamination of breathing zones, pre-entry checks and confined space entry
Specification
Application Range  
Standard Measuring Range: 0.2 to 5 ppm
Number of Strokes n: 20
Time for Measurement: approx. 30 min
Standard Deviation: ± 15 to 30 %
Color Change: pale yellow --> greyish blue
   
Ambient Operating Conditions  
Temperature: 10 to 40 °C
Absolute Humidity: 5 to 20 mg H2O / L
   
Reaction Principle  
CH2=CH2 + Pd-Molybdate complex --> blue reaction product
 
Cross Sensitivity
Other similar compounds are indicated in addition to ethylene, e.g.:
100 ppm butadiene result in a reading of 1 ppm
50 ppm butylene result in a reading of 1 ppm
5 ppm propylene result in a reading of 1 ppm
20 ppm hydrogen sulfide result in a reading of 2 ppm
25 ppm CO change the indicating layer to a greyish blue.