Drager Detection Tubes - Mercaptan 0.1/a (Pack of 10)

These short-term detection tubes from Drager Safety are for Mercaptans (0.1/a).  They have a measurement range 0.1 to 15 ppm.

The tubes come in a pack of 10 tubes and have a shelf life of 2 years.

Buy the Drager Accuro Gas Detection Pump by clicking here .  This is required for the use of short-term gas detection tube.

Key Features

  • Hard-to-reach places can be accessed and measured using various compatible accessories
  • Excellent for on-the-spot measurements
  • 10 seconds to 15 minutes is the time frame for readings and is totally dependent on the tube type
  • Suitable applications include pre-entry checks, confined space entry; variations in concentration levels and also contamination of breathing areas are amongst a number of potential of applications
Specification
Application Range  
Standard Measuring Range: 0.1 to 2.5 ppm / 3 to 15 ppm
Number of Strokes n: 10 / 2
Time for Measurement: approx. 3 min / approx. 40 s
Standard Deviation: ± 10 to 15 %
Color Change: yellow --> red
   
Ambient Operating Conditions  
Temperature: 5 to 40 °C
Absolute Humidity: 2 to 40 mg H2O / L
   
Reaction Principle  
2 R-SH + Hg Cl2 --> Hg(CH3S)2 + 2 HCl
HCl + pH-indicator --> reddish reaction product
 
Cross Sensitivity
Propyl mercaptan and n-butyl-mercaptan are indicated, but with different sensitivities. 4 ppm ethylene, 30 ppm CO, 10 ppm tetrahydrothiophene and 100 ppm hydrogen sulfide do not affect the indication. Hydrogen sulfide changes the pre-layer to black.