Drager Short Term Detection Tubes - Methylene Chloride 20/a (Pack of 10)

PRODUCT CODE:
8103591
Drager Detection Tubes - Methylene Chloride 20/a (Pack of 10)
£105.90 inc VAT
£88.25
Loading...

Product description

Drager Short Term Detection Tubes - Methylene Chloride 20/a (Pk of 10)

These Drager short-term detection tubes for Methylene Chloride (20/a) and have a measurement range of 20 to 200 ppm.  They are able to detect other substances including Dichloromethane.

This product has a shelf life of 2 years and comes in a pack of 10 tubes.

The Accuro Gas Detection Pump from Draeger Safety is required to use short-term gas detection tubes.  View more information on this product by clicking here

Key Features

  • Hard-to-reach places can be accessed and measured using various compatible accessories
  • Excellent for on-the-spot measurements
  • 10 seconds to 15 minutes is the time frame for readings and is totally dependent on the tube type
  • Suitable applications include pre-entry checks, confined space entry, variations in concentration levels and also contamination of breathing areas are amongst a number of potential of applications
Specification
Application Range  
Standard Measuring Range: 20 to 200 ppm
Number of Strokes n: 8
Time for Measurement: 7
Standard Deviation: ± 15 to 25 %
Color Change: yellow --> red
   
Ambient Operating Conditions  
Temperature: 17 to 30 °C
At 25 °C to 30 °C/77 °F to 86 °F
multiply the reading with the factor 0.6.
Absolute Humidity: 3 to 25 mg H2O / L
   
Reaction Principle  
a) CH2CI2 + chromate --> CI2
b) CI2 + amine --> red reaction product
 
Cross Sensitivity
100 ppm n-octane and 300 ppm carbon monoxide do not interfere the reading. In case of concentrations > 100 ppm n-octane, methylene chloride is not indicated. Other chlorinated hydrocarbons will be indicated.