Drager Ethanol 1000/a-D (1000-25000 ppm x h) Diffusion Tube
Drager Ethanol 1000/a-D (Measuring: 1,000 to 25,000 ppm x h) - Max. Oper. Time: 8 hrs.
Note: This product has a shelf life of 2 years.
Application Range | |
Standard Range | Measurement Time |
1,000 to 25,000 ppm | 1 h |
500 to 12,500 | 2 h |
200 to 5,000 ppm |
4 h |
125 to 3,100 ppm | 8 h |
Standard Deviation | ± 20 to 25 % |
Color Change | yellow - green |
Ambient Operating Conditions
Temperature | 0 to 40 °C |
Absolute Humidity | 1 to 16 mg H2O / L |
Reaction Principle
H3C-CH2OH + CrVI - CrIII + various oxidation products
Cross Sensitivity
Other organic compounds are also indicated, but with different sensitivities. It is impossible to differentiate between them. Methyl ethyl ketone and methanol are indicated with about twice the sensitivity (e.g. 500 ppm x h MEK gives an indication of 1,000 ppm x h).
Isopropanol is indicated with about half the sensitivity. Acetone and ethyl acetate in the TLV range have no influence on the indication.
Application Range | |
Standard Range | Measurement Time |
1,000 to 25,000 ppm | 1 h |
500 to 12,500 | 2 h |
200 to 5,000 ppm |
4 h |
125 to 3,100 ppm | 8 h |
Standard Deviation | ± 20 to 25 % |
Color Change | yellow - green |
Ambient Operating Conditions | |
Temperature | 0 to 40 °C |
Absolute Humidity | 1 to 16 mg H2O / L |
Reaction Principle | |
H3C-CH2OH + CrVI --> CrIII + various oxidation products | |
Cross Sensitivity | |
Other organic compounds are also indicated, but with different sensitivities. It is impossible to differentiate between them. Methyl ethyl ketone and methanol are indicated with about twice the sensitivity (e.g. 500 ppm x h MEK gives an indication of 1,000 ppm x h). Isopropanol is indicated with about half the sensitivity. Acetone and ethyl acetate in the TLV range have no influence on the indication. |