Drager Phosgene (0-3 ppm) Sensor

PRODUCT CODE:
6808582
Drager Phosgene (0-3 ppm) Sensor
£808.21 inc VAT
£673.51
Loading...

Product description

Drager Phosgene (0-3 ppm) Sensor

This DragerSensor XS EC is for Phosgene gas (COCI2) and is compatible with the X-am 7000 multi gas detector.  It has a measurement range of 0 to 10 ppm and has a guarantee of 6 months.

Suitable market segments for this type of sensor may include the production of plastics, insecticide production and also dyes.

Key Features

  • Highly selective filter against hydrogen chloride
  • Easily replaceable sensor
  • Plug and play sensor
Specification

Detection Limit

0.01 ppm

Resolution

0.01 ppm

Response Time

≤ 20 seconds at 20 °C or 68 °F (T20)

≤ 40 seconds at 20 °C or 68 °F (T50)

Measurement accuracy

Zero Point:  ≤ ± 0.01 ppm

Sensitivity:  ≤ ± 10% of measured value

Long-term drift, at 20°C (68°F)

Zero Point:  ≤ ± 0.01 ppm/month

Sensitivity:  ≤ ± 2% of measured value/month

Warm-up time:

≤ 1 hour

Ambient conditions

Temperature: (–20 to 40)°C (–4 to 104)°F Humidity: (10 to 90)% RH

Pressure: (700 to 1,300) hPa

Influence of Temperature

Zero Point:  ≤ ± 0.001 ppm/K

Sensitivity:  ≤ ± 1% of measured value/K

Influence of Humidity

Zero Point:  No effect

Sensitivity:  ≤ ± 0.05% of measured value/% RH

Test Gas

COCl2 test gas between 40% and 100% of highest figure in the set

measurement range.