Drager Short Term Detection Tubes - Cyanogen Chloride 0.25/a (Pack of 10)

PRODUCT CODE:
CH19801

These tubes are designed for spot-measurements and must be used with the Drager Accuro Gas Detection Pump. Buy now from Frontline Safety.

£137.68 inc VAT
£114.73
Loading...

Product description

Drager Short Term Detection Tubes - Cyanogen Chloride 0.25/a (Pack of 10)

Worldwide, the Dräger short-term detector tubes have proven to be a very cost-effective and reliable way for the measurement of gas. Cyanogen Chloride 0.25/a (Measurement range: 0.25 to 5 ppm). 

Note: This product has a shelf life of 2 years and comes in a pack of 10 tubes.

Specification
Application Range  
Standard Measuring Range: 0.25 to 5 ppm
Number of Strokes n: 20 to 1
Time for Measurement: max. 5 min
Standard Deviation: ± 30 %
Color Change: white --> pink
   
Ambient Operating Conditions  
Temperature: 5 to 40 °C
Absolute Humidity: < 50 mg H2O / L
   
Reaction Principle  
a) CICN + pyridine --> glutaconaldehyde cyanamide
b) Glutaconaldehyde + barbituric acid --> pink reaction product
 
Cross Sensitivity
Cyanogen bromide is indicated as well, but with a different sensitivity. Calibration data is not available.
 
Additional Information
Before performing the measurement the reagent ampoule must be broken and the liquid transferred onto the indicating layer so that it is completely saturated.