Drager Short Term Detection Tubes - Mercury Vapour 0.1/b (Pack of 10)

PRODUCT CODE:
CH23101

These tubes are designed for spot-measurements and must be used with the Drager Accuro Gas Detection Pump. Buy now from Frontline Safety.

£96.44 inc VAT
£80.37
Loading...

Product description

Drager Short Term Detection Tubes - Mercury Vapour 0.1/b (Pack of 10)

This particular Drager short-term detection tube is for Mercury Vapour (0.1/b).  It has a measurement range of 0.05 to 2 mg/m3 and has a shelf life of 2 years.

Please note one pack contains 10 tubes.

Buy the Drager Accuro Gas Detection Pump by clicking here .  This is required for the use of short-term gas detection tube.

Key Features

  • Hard-to-reach places can be accessed and measured using various compatible accessories
  • Excellent for on-the-spot measurements
  • 10 seconds to 15 minutes is the time frame for readings and is totally dependent on the tube type
  • Suitable applications include pre-entry checks, confined space entry, variations in concentration levels and also contamination of breathing areas are amongst a number of potential of applications
Specification
Application Range  
Standard Measuring Range: 0.05 to 2 mg/m3
Number of Strokes n: 40 to 1
Time for Measurement: max. 10 min
Standard Deviation: ± 30 %
Color Change: pale yellow grey --> pale orange
   
Ambient Operating Conditions  
Temperature: 0 to 40 °C
Absolute Humidity: < 20 mg H2O / L
   
Reaction Principle  
Hg + Cul --> Cu-Hg-complex
 
Cross Sensitivity
Free halogens cause substantial minus errors. It is impossible to measure mercury vapor in the presence of halogens. Arsine, phosphine, hydrogen sulfide, ammonia, nitrogen dioxide, sulfur dioxide and hydrazine in the TLV range do not interfere.