Drager Short Term Detection Tubes - Organic Arsine (Pack of 10)

PRODUCT CODE:
CH26303

These tubes are designed for spot-measurements and must be used with the Drager Accuro Gas Detection Pump. Buy now from Frontline Safety.

£137.68 inc VAT
£114.73
Loading...

Product description

Drager Short Term Detection Tubes - Organic Arsine (Pack of 10)

Worldwide, the Dräger short-term detector tubes have proven to be a very cost-effective and reliable way for the measurement of gas. Drager Short Term Detection Tubes - Organic Arsine. 

Note: This product has a shelf life of 2 years and comes in a pack of 10 tubes.

 

Specification
APPLICATION RANGE 
Standard Measuring Range

Qualitative

0.1 ppm Arsine and 3 mg org. arsenic/m3 are the minimum detectable concentrations.

Number of Strokes n 8
Time for Measurement max. 3 min
Standard Deviation ± 50 %
Color Change yellow to grey
   
AMBIENT OPERATING CONDITIONS
Temperature 0 to 40 °C
Absolute Humidity max. 50 mg H2O / L
   
REACTION PRINCIPLE

a) AsR3 + Zn/HCl to AsH3

b) AsH3 + Au/Hg-complex to Au (colloidal)

   
CROSS SENSITIVITY
Phosphine and arsine are indicated before the ampoule is broken, but with different sensitivities.
 
ADDITIONAL INFORMATION
Arsine is present if a grey ring appears in the indicating layer after performing 8 pump strokes. If there is no indication, the ampoule must be broken and the liquid transferred onto the indicating layer such that it is completely saturated. Then an additional eight pump strokes must be performed.