Drager Short Term Detection Tubes - Ozone 10/a (Pack of 10)

PRODUCT CODE:
CH21001

These tubes are designed for spot-measurements and must be used with the Drager Accuro Gas Detection Pump. Buy now from Frontline Safety.

Loading...
£107.38 inc VAT
£89.48

Product description

Drager Short Term Detection Tubes - Ozone 10/a (Pack of 10)

These short-term detection tubes have a measurement range of 2 to 300 ppm and have a shelf life of 2 years.  They come in pack of 10 tubes.

Short-term detection tubes require the use of the Drager Accuro Gas Detection Pump.  Click here to buy this product.

Key Features

  • Designed for short-term, on-the-spot measurement
  • Can take between 10 seconds to 15 minutes to gather a reading
  • Applications may include concentration fluctuations in the workplace, measurement of contaminants in breathing zone, and confined spaces
  • Can be used as pre-entry checks
Specification
Application Range  
Standard Measuring Range: 20 to 300 ppm
Number of Strokes n: 1
Time for Measurement: approx. 20 s
Standard Deviation: ± 10 to 15 %
Color Change: greenish blue --> yellow
   
Ambient Operating Conditions  
Temperature: 0 to 40 °C
Absolute Humidity: 2 to 30 mg H2O / L
   
Reaction Principle  
O3 + indigo --> isatine
 
Cross Sensitivity
No interference by:
1 ppm sulfur dioxide
1 ppm chlorine
1 ppm nitrogen dioxide.
Higher concentrations of chlorine and nitrogen dioxide discolor the indicating layer a diffuse yellowish grey.