    Drager X-am 5000 Multi-Gas Detector

    Dräger X-am 5000 Multi-Gas Detector – Configurable for Up to Five Gases

    A New Generation

    The Drager X-am 5000 multi gas detector is part of a new generation of gas detectors which have been developed specifically for personal monitoring applications.  This 1 to 5 gas detector reliably measures combustible gases and vapours as well as O2 and harmful concentrations of O3, Cl2, CO, CO H2-CP, CO2, H2, H2S, HCN, NH3, NO, NO2, PH3, SO2, COCl2, organic vapours, Odorant and Amine.  The detector has an integrated data logger and comes with the manufacturer’s and calibration certificates.

    Ergonomic Mobile Phone Design 

    The design of the X-am 5000 5 gas detector is similar to that of a practical mobile phone.  Despite its advanced functionality, it is light in weight and comfortable to carry.  The detector uses a two-button control panel with a large display, showing readings at a glance and an easy to follow menu to allow for intuitive use.   

    Drager’s multi gas detector is resistant to water and dust ingress according to IP 67 standards.  Even if the device is dropped into water it will still remain fully functional.  Additional resistance to impact and vibration is provided by the integrated rubber protection and shock-proof sensors.

    Continuous gas detection 

    This 5 gas detector has 2 gas inlets on the top and bottom of the surface which is designed to make sure multi gas detection is continuous even if the device is covered or put inside a pocket.  Other features which can be of use is the visible 360° alarm and retro reflective labels which are used so the instrument is easily visible in the dark or in water.  

    Durable Sensor Technology

    Drager uses innovative technology in its sensors, equipped with durable XXS sensor technology.  To assist multi gas detection, dependable warnings are given in the event of explosive atmospheres thanks to the high level of sensitivity of the innovative catalytic Ex sensor.  This has a quick response to explosive gases and combustible organic vapours.  It is also highly resistant against sensor poisons such as silicone and hydrogen sulfide.  

    The sensors are easy to exchange, upgrade or calibrate to other gases.  This makes more applications possible, including rental equipment.  There is a long expected sensor lifetime of more than 4 years which is beneficial in reducing your operational costs.  

    Other Features and Accessories

    The Drager X-am 5000 is compatible with various other accessories including an external pump, the Drager X-zone 5000 and Drager E-Cal automatic test and calibration station and the Drager Bump Test Station.  

    The optional external pump external pump, which operates with a hose up to 98 feet long, makes it possible to use the detector for pre-entry measurements into confined spaces such as tanks and shafts.  

    The multi gas detector can be used with the Drager X-zone 5000 for various area monitoring applications.  Up to 25 Drager X-zone 5000 units can be automatically interconnected to form a wireless fence line. This interconnection of the area monitoring devices allows for the fast securing of larger areas, e.g. pipelines or industrial tanks – even within the scope of industrial shutdowns.

    The automatic test and calibration station and bump test station allow fresh air, mixed gas and single gas calibrations to be done directly using the X-am 5000 menu.  Both of these system extensions can save time and reduce workload.  

    Flexible Power Supply

    In terms of power supply standard alkaline or rechargeable NilMh batteries can be used with the Drager X-am 5000.  Alternatively, a T4 battery can be fitted and can be charged whilst still inside the instrument.  There is an optional Save Energy Mode available which is beneficial in increasing the operating time of the detector to more than 40 hours.  

    Find the transport Case for Drager X-am here

    Key Features
    • Gas Inlets: At the top and the bottom for safe readings
    • Visual Alarm: 360° visible alarm
    • DragerSensors: Fast, accurate and reliable
    • Retro reflective Label: Easy to find in the dark or in water
    • Large Display: All readings at one glance
    Specifications
    Gas 1 LEL
    Range (ppm) 0 to 100% LEL
    Resolution (ppm) 1% LEL
    Response Time (T90) 10 sec.
    Gas 2 Methane (CH4)
    Range (ppm) 0 to 100% Vol. CH4
    Resolution (ppm) 1% LEL
    Response Time (T90) 10 sec.
    Gas 3 Oxygen (O2)
    Range (ppm) 0 to 25% Vol.
    Resolution (ppm) 0.1% Vol.
    Response Time (T90) 10 sec.
    Size 48 x 130 x 44 mm; 1.89 x 5.12 x 1.73 in.
    Weight 220 - 250 g; 7.8 - 8.8 oz.
    Sensors
    • Cat Ex 125 PR
    • DrägerSensor XXS O2 Sensor
    Battery
    • Operating time:  > 12 hours (without Ex sensor > 700 hours) when using the Save Energy Mode > 40 hours
    • Charging time:  < 4 hours
    Alarms 
    • Visual - 360°
    • Audible - Multi-tone >90 dB at 30 cm
    • Vibrating 
    Data Logging Can be read out via Infrared > 1,000 hours with 5 gases and a recording interval of 1 value per minute
    Pump Operation Maximum hose length 30 m; 98 ft.
    IP Rating IP-67: Protects against dust, protects against immersion between 15cm and 1m depth
    Certifications 
    • ATEX I M1 Ex ia I; II 1G Ex ia IIC T3 (Zone 0); I M2 Ex d ia I; II 2G Ex d ia IIC T4/T3
    • EN 50104 (2002) + A1 (2004) (O2)
    • EN 60079-29-1:2007 (Methane to Nonane)
    • EN 50271:2001 (Software and Documentation)
    • UL Class I & II, Div. 1 Group A, B, C, D, E, F, G T.-Code T4/T3
    • CSA Class I, Div. 1 Group A, B, C, D T.-Code T4/T3
    • IECEx Ex ia I; Ex ia IIC T3; Ex d ia I; Ex d ia IIC T4/T3
    • CE-mark Electromagnetic compatibility Directive 2004/108/EG; EN 50270:2006
    • MED Marine Equipment Directive 96/98/EC
    • MSHA
    Operating Temperature -20 - +50 °C; -4 - 122 °F
    Pressure 700 - 1300 hPa
    Humidity 10 - 95% r.h.
    What's Included
    • Drager X-am 5000 Monitor
    • Cat Ex 125 PR and DrägerSensor XXS O2 Sensors
    • Crocodile clip
    • NiMH rechargeable power pack and charger
    • Operation and Maintenance manual
    Take advantage of our web-exclusive free UK mainland* delivery offer on orders over £100 ex VAT.  See all costs for delivery below and visit our main delivery page for more information on timescales as some restrictions may apply.

    UK & Ireland Delivery Options

    UK Mainland Standard Delivery on orders under £100 ex VAT - £7.95 ex VAT*
    UK Mainland Express Delivery - £21.50 ex VAT (timescales vary – please see delivery page)
    Highlands Delivery - £25.00 ex VAT
    Channel Island Delivery - £40 ex VAT
    Northern Ireland & Republic of Ireland - £25 ex VAT
    Saturday Delivery Options – Please contact us on 0141 771 7749 for more info

    Standard delivery timescales are normally 3-5 working days, depending on stock availability.  Express delivery is normally 1-3 working days, depending on stock availability.  Although we carry an extensive stock, there may be some items that are unavailable due to quantities or otherwise.  In this case we will inform you of the status of your order and whether or not it can be fulfilled within our standard delivery timeframe. *Mainland UK delivery excludes Northern Ireland, other charges apply.

    Please visit our main delivery page for more terms and conditions or contact our Sales Team on 0141 771 7749  or [email protected] for more information. Currently, some manufacturers are facing production and delivery issues due to Brexit and custom clearance and this is affecting lead times of even some of our standard stocked items. We're trying our best to prevent these issues from affecting orders but please be aware that there may be some delays. We are aiming to communicate this as best and as early as possible.

    International Delivery Options

    Delivery costs vary between countries.  Please visit our main delivery page for more information.

    You also have the option to 'Arrange Your Own Courier', whereby you organise the shipment of your own goods once they have reached our warehouse.

    ORDER CANCELLATION AND GOODS RETURN

    Should you wish to cancel an order or return unwanted goods please follow the procedures detailed below to help us ensure cancellations/returns are processed as quickly and efficiently as possible.

    Simply log on to your customer account, note the order reference number and email the full cancellation details to [email protected] or contact us on 0141 771 7749. Assuming the order has not been despatched we will cancel.

    You have the right to cancel the purchase of goods without having to give a reason at any time within the “cooling off period” of fourteen working days, beginning the day after you take delivery of your order.

    You must notify us of your cancellation in writing via email to [email protected] or to our contact address. (Details Here)

    If you are in possession of the goods you are under the duty to retain them and take reasonable care of them.

    You must send the goods back to us in their original condition to our contact address at your own cost (unless we delivered the item to you in error or the item is damaged or defective) as soon as possible once you have cancelled the contract.

    Alternatively we will collect the goods from you which will incur a charge no greater than the actual cost of arranging the collection and shipping. In this case you must make the goods available for collection. We will contact you to make further arrangements.

    We reserve the right to make a charge not exceeding our direct costs of recovering the goods if you do not return the goods or return them at our expense.

    Upon receipt of returned items in satisfactory condition we will arrange a full credit by the same method used to pay for the goods originally. Any credit due will be processed within a maximum of thirty days.

    Note: If you wish to return goods for refund or exchange after 14 days, a re-stocking fee of 20% of the full order total will apply.

    If upon receipt of goods you find them to be faulty, damaged or if you have been incorrectly supplied an item, you should notify us within 24 hours by contacting 0141 771 7749 or [email protected] and quoting your order number and contact details.

    Frontline Safety will arrange uplift of any damaged or wrongly received goods and if on inspection of goods we also find them to be damaged, faulty or incorrectly supplied, we will offer replacement goods or provide a full refund.

    We recommend you inspect all goods prior to signing for and accepting delivery. If there is any visible damage to the outer packaging, ensure goods are sign for as damaged. In instances where it isn’t possible to sign for goods as damaged, these should be signed for as unexamined.


    Note: If your goods happen to develop a fault out with the standard returns period but within supplied warranty period or if you require any additional assistance, please contact us on 0141 771 7749 or email [email protected]

    IMPORTANT INFORMATION

    All postage, handling, customs and duty charges for all returned goods are the responsibility of the customer. We recommend using a fully traceable, insured service as goods are your responsibility while in transit.

    Dräger X-am 5000 Multi-Gas Detector – Configurable for Up to Five Gases

    A New Generation

    The Drager X-am 5000 multi gas detector is part of a new generation of gas detectors which have been developed specifically for personal monitoring applications.  This 1 to 5 gas detector reliably measures combustible gases and vapours as well as O2 and harmful concentrations of O3, Cl2, CO, CO H2-CP, CO2, H2, H2S, HCN, NH3, NO, NO2, PH3, SO2, COCl2, organic vapours, Odorant and Amine.  The detector has an integrated data logger and comes with the manufacturer’s and calibration certificates.

    Ergonomic Mobile Phone Design 

    The design of the X-am 5000 5 gas detector is similar to that of a practical mobile phone.  Despite its advanced functionality, it is light in weight and comfortable to carry.  The detector uses a two-button control panel with a large display, showing readings at a glance and an easy to follow menu to allow for intuitive use.   

    Drager’s multi gas detector is resistant to water and dust ingress according to IP 67 standards.  Even if the device is dropped into water it will still remain fully functional.  Additional resistance to impact and vibration is provided by the integrated rubber protection and shock-proof sensors.

    Continuous gas detection 

    This 5 gas detector has 2 gas inlets on the top and bottom of the surface which is designed to make sure multi gas detection is continuous even if the device is covered or put inside a pocket.  Other features which can be of use is the visible 360° alarm and retro reflective labels which are used so the instrument is easily visible in the dark or in water.  

    Durable Sensor Technology

    Drager uses innovative technology in its sensors, equipped with durable XXS sensor technology.  To assist multi gas detection, dependable warnings are given in the event of explosive atmospheres thanks to the high level of sensitivity of the innovative catalytic Ex sensor.  This has a quick response to explosive gases and combustible organic vapours.  It is also highly resistant against sensor poisons such as silicone and hydrogen sulfide.  

    The sensors are easy to exchange, upgrade or calibrate to other gases.  This makes more applications possible, including rental equipment.  There is a long expected sensor lifetime of more than 4 years which is beneficial in reducing your operational costs.  

    Other Features and Accessories

    The Drager X-am 5000 is compatible with various other accessories including an external pump, the Drager X-zone 5000 and Drager E-Cal automatic test and calibration station and the Drager Bump Test Station.  

    The optional external pump external pump, which operates with a hose up to 98 feet long, makes it possible to use the detector for pre-entry measurements into confined spaces such as tanks and shafts.  

    The multi gas detector can be used with the Drager X-zone 5000 for various area monitoring applications.  Up to 25 Drager X-zone 5000 units can be automatically interconnected to form a wireless fence line. This interconnection of the area monitoring devices allows for the fast securing of larger areas, e.g. pipelines or industrial tanks – even within the scope of industrial shutdowns.

    The automatic test and calibration station and bump test station allow fresh air, mixed gas and single gas calibrations to be done directly using the X-am 5000 menu.  Both of these system extensions can save time and reduce workload.  

    Flexible Power Supply

    In terms of power supply standard alkaline or rechargeable NilMh batteries can be used with the Drager X-am 5000.  Alternatively, a T4 battery can be fitted and can be charged whilst still inside the instrument.  There is an optional Save Energy Mode available which is beneficial in increasing the operating time of the detector to more than 40 hours.  

    Find the transport Case for Drager X-am here

    Key Features
    • Gas Inlets: At the top and the bottom for safe readings
    • Visual Alarm: 360° visible alarm
    • DragerSensors: Fast, accurate and reliable
    • Retro reflective Label: Easy to find in the dark or in water
    • Large Display: All readings at one glance
    Specifications
    Gas 1 LEL
    Range (ppm) 0 to 100% LEL
    Resolution (ppm) 1% LEL
    Response Time (T90) 10 sec.
    Gas 2 Methane (CH4)
    Range (ppm) 0 to 100% Vol. CH4
    Resolution (ppm) 1% LEL
    Response Time (T90) 10 sec.
    Gas 3 Oxygen (O2)
    Range (ppm) 0 to 25% Vol.
    Resolution (ppm) 0.1% Vol.
    Response Time (T90) 10 sec.
    Size 48 x 130 x 44 mm; 1.89 x 5.12 x 1.73 in.
    Weight 220 - 250 g; 7.8 - 8.8 oz.
    Sensors
    • Cat Ex 125 PR
    • DrägerSensor XXS O2 Sensor
    Battery
    • Operating time:  > 12 hours (without Ex sensor > 700 hours) when using the Save Energy Mode > 40 hours
    • Charging time:  < 4 hours
    Alarms 
    • Visual - 360°
    • Audible - Multi-tone >90 dB at 30 cm
    • Vibrating 
    Data Logging Can be read out via Infrared > 1,000 hours with 5 gases and a recording interval of 1 value per minute
    Pump Operation Maximum hose length 30 m; 98 ft.
    IP Rating IP-67: Protects against dust, protects against immersion between 15cm and 1m depth
    Certifications 
    • ATEX I M1 Ex ia I; II 1G Ex ia IIC T3 (Zone 0); I M2 Ex d ia I; II 2G Ex d ia IIC T4/T3
    • EN 50104 (2002) + A1 (2004) (O2)
    • EN 60079-29-1:2007 (Methane to Nonane)
    • EN 50271:2001 (Software and Documentation)
    • UL Class I & II, Div. 1 Group A, B, C, D, E, F, G T.-Code T4/T3
    • CSA Class I, Div. 1 Group A, B, C, D T.-Code T4/T3
    • IECEx Ex ia I; Ex ia IIC T3; Ex d ia I; Ex d ia IIC T4/T3
    • CE-mark Electromagnetic compatibility Directive 2004/108/EG; EN 50270:2006
    • MED Marine Equipment Directive 96/98/EC
    • MSHA
    Operating Temperature -20 - +50 °C; -4 - 122 °F
    Pressure 700 - 1300 hPa
    Humidity 10 - 95% r.h.
    What's Included
    • Drager X-am 5000 Monitor
    • Cat Ex 125 PR and DrägerSensor XXS O2 Sensors
    • Crocodile clip
    • NiMH rechargeable power pack and charger
    • Operation and Maintenance manual
    Take advantage of our web-exclusive free UK mainland* delivery offer on orders over £100 ex VAT.  See all costs for delivery below and visit our main delivery page for more information on timescales as some restrictions may apply.

    UK & Ireland Delivery Options

    UK Mainland Standard Delivery on orders under £100 ex VAT - £7.95 ex VAT*
    UK Mainland Express Delivery - £21.50 ex VAT (timescales vary – please see delivery page)
    Highlands Delivery - £25.00 ex VAT
    Channel Island Delivery - £40 ex VAT
    Northern Ireland & Republic of Ireland - £25 ex VAT
    Saturday Delivery Options – Please contact us on 0141 771 7749 for more info

    Standard delivery timescales are normally 3-5 working days, depending on stock availability.  Express delivery is normally 1-3 working days, depending on stock availability.  Although we carry an extensive stock, there may be some items that are unavailable due to quantities or otherwise.  In this case we will inform you of the status of your order and whether or not it can be fulfilled within our standard delivery timeframe. *Mainland UK delivery excludes Northern Ireland, other charges apply.

    Please visit our main delivery page for more terms and conditions or contact our Sales Team on 0141 771 7749  or [email protected] for more information. Currently, some manufacturers are facing production and delivery issues due to Brexit and custom clearance and this is affecting lead times of even some of our standard stocked items. We're trying our best to prevent these issues from affecting orders but please be aware that there may be some delays. We are aiming to communicate this as best and as early as possible.

    International Delivery Options

    Delivery costs vary between countries.  Please visit our main delivery page for more information.

    You also have the option to 'Arrange Your Own Courier', whereby you organise the shipment of your own goods once they have reached our warehouse.

    ORDER CANCELLATION AND GOODS RETURN

    Should you wish to cancel an order or return unwanted goods please follow the procedures detailed below to help us ensure cancellations/returns are processed as quickly and efficiently as possible.

    Simply log on to your customer account, note the order reference number and email the full cancellation details to [email protected] or contact us on 0141 771 7749. Assuming the order has not been despatched we will cancel.

    You have the right to cancel the purchase of goods without having to give a reason at any time within the “cooling off period” of fourteen working days, beginning the day after you take delivery of your order.

    You must notify us of your cancellation in writing via email to [email protected] or to our contact address. (Details Here)

    If you are in possession of the goods you are under the duty to retain them and take reasonable care of them.

    You must send the goods back to us in their original condition to our contact address at your own cost (unless we delivered the item to you in error or the item is damaged or defective) as soon as possible once you have cancelled the contract.

    Alternatively we will collect the goods from you which will incur a charge no greater than the actual cost of arranging the collection and shipping. In this case you must make the goods available for collection. We will contact you to make further arrangements.

    We reserve the right to make a charge not exceeding our direct costs of recovering the goods if you do not return the goods or return them at our expense.

    Upon receipt of returned items in satisfactory condition we will arrange a full credit by the same method used to pay for the goods originally. Any credit due will be processed within a maximum of thirty days.

    Note: If you wish to return goods for refund or exchange after 14 days, a re-stocking fee of 20% of the full order total will apply.

    If upon receipt of goods you find them to be faulty, damaged or if you have been incorrectly supplied an item, you should notify us within 24 hours by contacting 0141 771 7749 or [email protected] and quoting your order number and contact details.

    Frontline Safety will arrange uplift of any damaged or wrongly received goods and if on inspection of goods we also find them to be damaged, faulty or incorrectly supplied, we will offer replacement goods or provide a full refund.

    We recommend you inspect all goods prior to signing for and accepting delivery. If there is any visible damage to the outer packaging, ensure goods are sign for as damaged. In instances where it isn’t possible to sign for goods as damaged, these should be signed for as unexamined.


    Note: If your goods happen to develop a fault out with the standard returns period but within supplied warranty period or if you require any additional assistance, please contact us on 0141 771 7749 or email [email protected]

    IMPORTANT INFORMATION

    All postage, handling, customs and duty charges for all returned goods are the responsibility of the customer. We recommend using a fully traceable, insured service as goods are your responsibility while in transit.

    Product Video