Drager X-am 5000 Gas Detection Kit CatEx/O2

PRODUCT CODE:
3359310
Drager X-am 5000 Gas Detection Kit CatEx/O2
£1,788.56 inc VAT
£1,490.47

Additional services

  • £50.00
Gas detection equipment requires service and calibration every 6 months. In acknowledgement of this we are offering you your first calibration at a special rate.
Loading...

Product description

Drager X-am 5000 Gas Detection Kit CatEx/O2

The Drager X-am 5000 is ideal for personal monitoring applications and can be used in potentially explosive atmospheres.  This particular monitor features a combustible gas Ex sensor and also an O2 oxygen sensor.

It has the ability to detect up to five gases using XXS sensors.  The catalytic Ex sensor has a high level of sensitivity high resistance against sensor poisons such as silicone and hydrogen sulphide.

Have confidence that your monitor will be able to withstand tough conditions and safely detect oxygen depletion and combustible gases with its rubber housing and shock-proof sensors.

The X-zone 5000 can be used in conjunction with the X-am 5000 to carry out area monitoring applications and the Drager Bump Test Station and X-dock testing and calibration station can both be used to carry out functional tests and bump tests.

Key Features

  • Resistant to electromagnetic interference
  • External pump available  for pre-entry checks into confined spaces such as tanks, shafts etc.
  • Retro-reflective label makes it easy to find in the dark
  • Large display shows readings at a glance
  • Energy save mode makes it possible to increase operating time to more than 40 hours
  • Datalogging capability – can be read out via Infrared
  • >1000 hours with 5 gases and a recording interval of 1 value per minute
  • Gas inlets featured at the top and bottom of the device
Specification
Range (ppm)
  • 0 to 100% LEL
  • 0 to 100 Vol. -% CH4
  • 0 to 25 Vol. -% O2
Resolution (ppm)
  • 1% LEL
  • 0.1 Vol.-% - O2
Response Time (T90)
  • 10 sec (Ex and O2)
Dimensions 48 x 130 x 44 mm; 1.89 x 5.12 x 1.73 in.
Weight 220 - 250 g; 7.8 - 8.8 oz.
Ambient Conditions
  • Temperature: -20 - +50 °C
  • Pressure: 700 - 1300 mbar
  • Humidity: 10 - 95% r.h.
Operating Time >12 hours (without Ex sensor > 700 hours), >40 hours – save energy mode
Charging Time  < 4 hrs
IP Rating IP 67 – water and dust resistant
Alarms
  • Visual (360°)
  • Audible (multi-tone >90 dB at 30cm)
  • Vibrating
Expected Service Life
  • CatEx - >4 years
  • O2, CO & H2S - >5 years
Certifications 
  • ATEX – I M1 Ex ia I II 1G Ex ia IIC T3 (Zone 0) I M2 Ex d ia I II 2G Ex d ia IIC T4/T3 Measurement performance certificate according to: EN 50104 (2002)+A1(2004) – O2 EN 60079-29-1:2007 – Methane to Nonane EN 50271:2001 – Software and documentation
  • UL – Class I & II, Div 1 Group A, B, C, D, E, F, G T-Code T4/T3
  • CSA – Class I Div. 1 Group A, B, C, D, T.-Code T4/T3
  • IECEx – Ex ia I Ex ia IIC T3 Ex d ia I Ex d ia IIC T4/T3
  • CE Mark – Electromagnetic Compatibility (Directive 2004/108/EG); EN 50270:2006
  • MED – Marine Equipment Directive (Directive 96/98/EC)
  • MSHA
What's Included
  • Drager X-am 5000 Monitor with specified sensors
  • Crocodile clip
  • NiMH rechargeable power pack and charger
  • Operation and Maintenance manual