Drager X-am Pump
The Drager X-am External Pump is suitable for use with a range of Drager Multi Gas Detectors. This includes the Drager X-am 2500, 5000 and 5600. It comes with a pump, external filters and a USB charging cable.
Please note: X-am units require 7.1 software version to be compatible with this pump. The X-am gas detector must be purchased separately.
The combination of the pump and detector means clearance measurements can be carried out in applications and areas such as tanks and shafts. When connected to the X-am detector the pump will automatically switch on. One removed the pump will automatically switch off.
Changing from pump mode to diffusion mode is quick and easy to do. There’s no buttons so operation of the device is simple. The external pump clips safely on to the X-am gas detector and is self-starting. Any warning signals on the device will still remain visible.
The pump operating time, charge status, battery warnings and flow alarm are all displayed on the X-am and stored in its data logger.
- Rechargeable battery which can be charged via a micro USB port
- Connection available for hoses with a 3 or 5mm diameter
- Can utilise hoses up to 45m in length
- Charging status indicated by an LED on the pump
- Takes 6 hours to recharge
- IP67 rated
- Solid cast battery which protects against any damage due to dropping or impact
Dimensions |
67 x 175 x 38 mm (without X-am®), 67 x 220 x 55 mm (with X-am®) |
Weight |
200g |
Operating Temperature |
-20 °C to 50 °C (briefly -40 °C) |
Temperature when charging |
0 – 35 °C |
Operating Time |
Up to 20 hours (depending on application and temperature) |
Air Flow Volume |
0.4 L/min |
Storage Temperature |
Up to 1 month -20 °C to 60 °C, otherwise -20 °C to 45 °C |
Pressure |
700 to 1300 hPa |
Air Humidity |
0 to 95 % RH |
Approvals |
c_CSA_us |