Drager XXS OV (0-200 ppm) Sensor

This DragerSensor XXS is suitable for organic vapours and has various measurement ranges.

It can be used in the Drager Pac 7000, X-am 5600 and the X-am 5000 gas detection monitors and is suitable for industries such as the product of plastics, disinfection, painting, chemical industry and also pest control.

The measurement ranges for various substances can be found below: 

  • 0 to 200 ppm C2H4O (ethylene oxide)
  • 0 to 200 ppm C3H6O (propylene oxide)
  • 0 to 100 ppm C2H4 (ethene)
  • 0 to 100 ppm C3H6 (propene)
  • 0 to 100 ppm C2H3Cl (vinyl chloride)
  • 0 to 200 ppm CH3OH (methanol)
  • 0 to 100 ppm CH2CHCHCH2 (butadiene)
  • 0 to 100 ppm HCHO (formaldehyde)
  • 0 to 300 ppm (H3C)2CHOH (isopropanol)
  • 0 to 200 ppm C4H8O (tetrahydrofuran)
  • 0 to 100 ppm C2H3OCH2CI (1-chloro-2,3 epoxypropane)
  • 0 to 100 ppm C6H5CHCH2 (styrol)
  • 0 to 100 ppm H2CC(CH3)COOCH3 (methyl methacrylate)

Key Features

  • Has a 1 year guarantee
  • Replaceable sensor
  • Suitable for detecting leakages of numerous organic gases and vapours
  • Is almost completely insensitive to moisture
  • Does not need to be calibrated every day
  • Has a 6-month calibration interval typical of EC sensors
Specification

Detection Limit

1 ppm

Resolution

0.5 ppm

Response Time

≤ 20 seconds at 20°C (T50) or 68°F

Measurement accuracy

Zero Point:  ≤ ± 3 ppm
Sensitivity:  ≤ ± 5% of measured value

Long-term drift, at 20°C (68°F)

Zero Point:  ≤ ± 5 ppm/year
Sensitivity:  ≤ ± 2% of measured value/month

Warm-up time:

≤ 18 hours

Ambient conditions

Temperature: (-20°C to 50°C)(-4 to 122°F)
Humidity: (10 to 90)% RH
Pressure: (700 to 1,300) hPa

Influence of Temperature

Zero Point:  ± 2 ppm (-20°C to 40°C)(-4 to 104°F)
Zero Point:  ± 0.5 ppm/k (-40°C to 50°C)(104 to 122°F)
Sensitivity:  ≤ ± 1% of measured value/K

Influence of Humidity

Zero Point:  No Effect
Sensitivity:  ≤ ± 0.2% of measured value/% RH

Test Gas

approx. 10 ppm C2H4O
The Drager Sensor XXS OV has a defined cross-sensitivity to carbon monoxide (CO). It can be calibrated with CO as a replacement for all of its target gases. This replacement calibration using CO can produce an additional measuring error of up to 20%. We recommend that devices are calibrated with the gas you intend to detect in actual operation. Calibration using the target gas is more accurate than replacement gas calibration.