DrugCheck 3000 IVD (Pack of 20)
Please note this product is no longer available. See 8325580 as a replacement.
The Drager DrugCheck 3000 is a disposable drug testing device designed to find out within minutes if a person has recently consumed certain drugs. Simultaneously check for cocaine (COC), opiates (OPI), amphetamine (AMP), methamphetamines/designer drugs (e.g. Ecstasy) and cannabis (THC).
The DrugCheck 3000 has the advantage of being compact and has no requirement of electricity, so it can effectively be used anywhere. It has two components: one is the absorbent collector for obtaining an oral fluid sample, and the other is a test cassette which is used for the analysis.
Carry out the test in three easy steps: swab the sample, shake the test kit and wait, and then start the test. Once the control lines appear in the window the results can be read. A negative DrugCheck 3000 will show a line next to the respective substance class (drug) and this means that none of the target substances were detected in that sample. If a line fails to appear next to any of the substance classes, then the result of the test will be positive.
Drager have also developed the DrugCheck 3000 app for smartphones. This can be used in conjunction with the test and it allows you to scan, analyse, log and archive test results. These results can be shown on the app, or they can be emailed.
- Funnel-shaped test opening which is where the absorbent collector is inserted
- Substance identification can be seen on the test strip through the window
- The absorbent collector features a colour indicator which disappears once enough liquid has been collected
- Safety flap protects against any accidental starts
- Optimised to detect THC.
- Entire test takes only 5-7 minutes
- Easy transport and available for use quickly
- Safe to use in hazardous areas
- Hygienic and unable to be manipulated
What it includes |
Pack of 20 DrugCheck 3000 |
Dimensions |
32 x 111 x 57 mm 1.26 x 4.37 x 2.24 inches |
Weight |
< 30 g (0,07 lb) |
Operating Range |
Operation: 5°C to 30°C (41°F to 86°F) at 5 % to 95 % relative humidity |
Storage / Transportation |
4°C to 25°C (39°F to 77°F) |
Time of Measurement |
Fast measurement: analysis < 5 minutes Sensitive measurement: analysis < 7 minutes |
Selecting the Measurement Mode |
Depending on the selected pre-incubation time and the desired THC cut-off fast or more sensitive reading. |
Licenses / Standard |
Licensed as a medical product within the EU in accordance with Directive 98/79/EC on in vitro diagnostic medical devices (IVD). |