Comes Supplied With
|
Quick Start Guide, USB-C Adaptor, 1m USB-C/A cable, flow adaptor for diffusion if applicable.
|
|
Alarms and Type
|
Visual, Vibrating, Audible (95 dB at 30 cm), 3 x Instantaneous, TWA, STEL, Negative Drift, Over Limit, Battery, System Integrity
|
|
Logged Information
|
Transmitter (enclosure only): Aluminium alloy: 2.45 kg.
316 stainless steel: 5.37 kg
Transmitter with display module: Aluminium alloy: 2.92 kg. 316 stainless steel: 5.84 kg
XPIS sensor module with cartridge: 0.80 kg
XP sensor module with cartridge: 0.69 kg
|
|
System Integrity
|
Event log: All system and sensor critical events with user acknowledgement where required
Data log: System and sensor specific readings at defined interval for 15-120 s (user configurable)
Configuration log: Factory default, instrument restore point (user configurable), current settings, with full change history)
Calibration history: Full calibration history of a given device up to and including last 10 calibrations
Advanced diagnostics: System, sensor, battery, and user operational-related log for maintenance and lifetime operation assistance
|
|
ActionTAGS
|
Full boot load, security, and diagnostic check on startup
USER tag: Easy identification of users or change of service e.g. “out for repair”
ACCESSORY tag: Tag sampling accessories for simple verification of gas type compatibility and set operation automatically
BUMP tag: Initiate a BUMP test by scanning a gas cylinder tag with full traceability and 100% validation
CALIBRATION tag: Read calibration gas cylinder set up and complete the “guided” calibration routine
LOCATION tag: Check an asset name, item number, verify location, or entry to a confined space, all of which can be programmed
All action TAGS are AES-128-bit encrypted or higher. User programmed via PC or mobile device software
|
|
Temperature
|
Certified: -20°C to 60°C (-4°F to 140°F), operational range is sensor dependent
|
|
Ingress Protection
|
Waterproof, independently tested IP66 & IP68 (diffusion), IP65 (pumped)
|
|
Humidity
|
Operating conditions dependent upon sensors. Generally, 0-99%rH (non-condensing) is recommended
|
|
Connectivity and Software
|
USB-C 5V 1-2A device controlled, Bluetooth® 5.X, NFC 13.56MHz contactless technology.
Supports NTAG424 DNA and DESFire EV2(3) for maximum data security and encryption to avoid cyber-attacks.
Operates with Device Configurator Mobile App (iOS, Android), Safety Suite 2.0, and PC Lite (Windows 11).
PC Lite included for fundamental system set-up and configuration, and data extraction, at the local point of use.
Safety Suite 2.0 is recommended for centralised fleet management and for generating custom reports across multiple locations.
|
|
Certifications and Approvals
|
Global intrinsic safety approvals; suitable for use Zone 0, 1, 2, Class 1, Division 1 & 2, explosive atmospheres.
Approved for indoor, outdoor, onshore, and offshore use by CSA (NRTL) to UL, CSA, IECEX, and ATEX requirements.
Approvals pending. Contact Honeywell for the latest availability by geography.
|