Honeywell Optima Plus - Ethylene

PRODUCT CODE:
HONEYWELL-OPTIMA-PLUS-ETHYLENE

The Searchpoint Optima Plus Ethylene has been designed by Honeywell with a long operating life and fast response speed to be used in potentially explosive atmospheres.

There is currently a global supply chain delay affecting the production of the Honeywell Searchpoint Optima Plus range. Please contact our sales team to find lead times for certain part numbers.

Loading...
£1,713.00
Final product price inc VAT

Product description

Searchpoint Optima Plus Ethylene

The Searchpoint Optima Plus Ethylene has a long operating life and a fast speed of response.  It can also be used in potentially explosive atmospheres. Designed by Honeywell, this system features reduced power consumption and improves reliability. The system has been designed to be used in applications including solvent printing and coating plants, tankers and offshore oil and gas platforms. For more information, please see the datasheet.

The system is available with the industry standard 4-20mA output or the HART (Highway Addressable Remote Transducer) communication method. The latter allows users to be able to access status indications and live data, as well as diagnostic data from intelligent field devices. This means users can gain more out of the Searchpoint Optima Plus Ethylene. The HART functionality means that users do not need to have dedicated handheld devices on the field as one can use a single HART system to gain access to any HART enabled systems on site.

Accessories for use with the system includes the XNX universal transmitter and HALO junction box. For more information on accessories please get in touch with us. The Searchpoint Optima Plus Ethylene has an increased false alarm rejection mechanism helping to ensure that the system provides users with the operational integrity of the highest level.

Available options include;

Part Number

Description

2108N4001H

Optima Plus Gas Detector, ethylene version, HART® over 4 to 20mA output, ATEX/IECEx, M25 thread spigot, electro polished 316SS, includes polyester mesh dust barrier, nylon weather protection housing and LNP Faradex deluge/sunshade

2108N5001H

Optima Plus Gas Detector, ethylene version for sampling systems, HART® over 4 to 20mA output, ATEX/IECEx, M25 thread spigot, electro polished 316SS, includes black anodised aluminium flow housing

2108N4001N

Optima Plus Gas Detector, ethylene version, 4 to 20mA output, ATEX/IECEx, M25 thread spigot, electro polished 316SS, includes polyester mesh dust barrier, nylon weather protection housing and LNP Faradex deluge/sunshade

2108N4011N

Optima Plus Gas Detector, ethylene version, 4 to 20mA output, ATEX/IECEx, M25 thread spigot, electro polished 316SS, includes pre-fitted remote gassing cell, polyester mesh dust barrier, nylon weather protection housing and LNP Faradex deluge/sunshade

2108N4011H

Optima Plus Gas Detector, ethylene version, HART® over 4 to 20mA output, ATEX/IECEx, M25 thread spigot, electro polished 316SS, includes pre-fitted remote gassing cell, polyester mesh dust barrier, nylon weather protection housing and LNP Faradex deluge/sunshade

2108N5001N

Optima Plus Gas Detector, ethylene version for sampling systems, 4 to 20mA output, ATEX/IECEx, M25 thread spigot, electro polished 316SS, includes black anodised aluminium flow housing

Key Features

  • Ingress protection of IP66/67
  • More reliable with no moving parts
  • Ethylene gas detector
  • Self-compensating optics result in increased stability
  • Optics of the system are condensation free as due to Dynamic Heating Control
Specification

Please view the datasheet for more information

Material

316 stainless steel

Weight

1.6kg

Measuring Range

0-100% LEL, wide selection of Hydrocarbon gas and vapour calibrations. Different measuring ranges and solvent calibrations available for specialist applications

Signal Output

4-20mA autosensing sink or source

Over Range

20-21.5mA (Default 21mA)

Response Time

T50 < 3 seconds, T90 < 4 seconds (Methane)

Operational and Certified**

-40°C to +65°C temperature range

**CU-TR-EX (Russia) Approval – XTC Version, Certified Temperature Range -60°C to + 65°C

Power Supply

18-32Vdc (24Vdc nom), < 4.5W max

Environmental Protection

IP 66 / 67

Accuracy

  • Optima Plus (Hydrocarbon) Baseline < ±1% FSD, 50% FSD <±2% FSD
  • Optima Plus (Ethylene) Baseline < ±2% FSD, 50% FSD <±3% FSD

Approvals

  • ATEX: Baseefa13ATEX0296X
  •  II 2 GD Ex d op is IIC Gb Ex tb IIIC Db
  • T96°C (Tamb -40°C to +65°C)
  • T86°C (Tamb -40°C to +55°C)
  • IP 66/67
  • UL / CSA: Class 1, Div 1, groups B, C, and D (-40°C to +65°C)
  • IECEx: II 2 GD Ex d op is IIC Gb Ex tb IIIC Db T86°C (Tamb -40°C to +55°C) or T96°C (Tamb -40°C to +65°C) IP66/67
  • CU-TR-EX (Russian Customs Union) - XTC Version 1Ex d op is IIC T5/T4 Gb X (Tamb -60°C to +65°C)

Performance approval

  • EN 60079-29-1 (BVS 03 ATEX G 016 X)
  • CSA C22.2 152.
  • FM ANSI/ISA-12.13.01.
  • Russian Pattern Approval (Metrology) - XTC Version

Functional Safety

IEC61508 Safety Integrity Level 2

Marine Approvals

Marine Equipment Directive (MED), type approvals from DNV, BV, ABS, Lloyd’s Register