large image
Over 6000 products
Loading...
PRODUCT CODE
SENSEPOINT-XCD-ALUMIN

For more information on the configuration of this fixed gas system and the various options available then speak to our Fixed Gas Detection Team on 0141 771 7749 and check out the product datasheet in the downloads tab below.

* Required Fields

    £1,018.80 £849.00

    Honeywell Sensepoint XCD - Aluminium

    Honeywell Sensepoint XCD - Aluminium 

    The Sensepoint XCD is an explosion-proof transmitter from Honeywell Analytics.  This provides monitoring for flammable, toxic and oxygen gas hazards in potentially explosive atmospheres.  This includes both indoor and outdoor applications. 

    The configurations listed above all have an aluminium enclosure. Stainless steel is also available.  Detectable Gases include: Oxygen, Hydrogen Sulphide, Carbon Monoxide, Hydrogen, Nitrogen Dioxide, Flammable, Methane, Propane, Carbon Dioxide

    Applications include Industrial manufacturing facilities, power plants, waste water facilities, utilities, food and beverage production, refineries and chemical plants, onshore oil and gas terminals, production platforms and exploration and drilling.

    Modifying the detectors operation can be done using the LCD screen and magnet switches.  There’s no need to open up the unit which will potentially prevent non-intrusive operation and will reduce maintenance time and costs.

    Key Features
    • User friendly and intuitive tri-colour backlit display with digits, bar graph and icons
    • Traffic light system indicates normal operation (green), faults (flashing yellow) and alarms (flashing red)
    • Can be placed on an integral mounting plate for surface mounting or can be mounted to a horizontal or vertical pipe using the optional pipe mounting bracket
    • Rated as IP66
    Specifications

    For full specification please   refer to the datasheet

    Standard Supply

    • Integral wall mounting plate, 2 x M20 cable entry (ATEX/IECEx) or 2 x   ¾”NPT conduit entries (UL/cUL),
    • 1 x M20 or 1 x ¾”NPT plug, Allen key for locking screw, weatherproof   cap, operating magnet, sensor cartridge with retainer, quick start guide and   instruction manual CD.  Default   settings, ranges and calibrations are 100% tested at the factory. Each unit   is supplied with a calibration and test certificate.

    Shipping carton dimensions:

    • L312mm (12.3”) x W223mm (8.8”) x D110mm (4.3”)
    • Approximate weight: Aluminium 2.5kg (5.5lbs)

    Certification

    •   European - ATEX II 2 GD Ex d IIC Gb T6 (Ta   -40ºC to +65ºC) T5 (Ta -40ºC to +75ºC) Ex tb IIIC T85°C Db IP66 T100ºC (Ta   -40ºC to +75ºC)
    •   International - IECEx Ex d IIC Gb T6 (Ta -40ºC   to +65ºC) T5 (Ta -40ºC to +75ºC) Ex tb IIIC T85°C Db IP66 T100ºC (Ta -40ºC to   +75ºC)
    •   China - GB Ex d IIC T4 GB3836.1&2 -2000,   PA, CCCF
    •   Korea - KTL Ex d IIC T6 (-40°C to +65°C)
    •   North America - UL/c-UL - Class I, Division 1,   Groups B, C and D, Class I, Division 2, Groups B, C & D, Class II,   Division 1, Groups E, F & G, Class II, Division 2, Groups F & G. -40ºC   to +65ºC
    •   EMC - EN50270:2006 EN6100-6-4:2007
    •   Performance - ATEX, EN60079-29-1:2007   (flammable), EN45544 (Toxic), EN50104 (Oxygen), EN50271
    •   China: PA Pattern Measurement (for transmitter   and toxic gas sensors)
    •   “CCCF” Shenyang for Flammable (fire dept   approval)
    •   CSA C22.2-152
    • Sensors

      SPXCDXSFXSS - Flammable CAT 0-100%LEL (20 to 100%LEL, 10%LEL)

      SPXCDXSRXSS - Methane IR 0-100%LEL (20 to 100%LEL, 10%LEL)

      SPXCDXSO1SS - Oxygen 25.0% v/v only

      SPXCDXSHXSS - Hydrogen Sulfide 0-50ppm (10.0 to 100.0ppm, 1ppm)

      SPXCDXSCXSS - Carbon Monoxide 0-300ppm (100 to 1000ppm, 100ppm)

      SPXCDXSNXSS - Nitrogen Dioxide 0-10ppm (10.0 to 50.0ppm, 5ppm)

      SPXCDXSG1SS - Hydrogen 0-1000ppm only

      SPXCDXSPXSS - Propane IR 0-100%LEL (20 to 100%LEL, 10%LEL)

      SPXCDXSB1SS - Carbon Dioxide IR 0-2.00% v/v only

      SPXCDXSB2SS - Carbon Dioxide IR 0-5.00% v/v only

    • Transmitters (without sensors)

      SPXCDALMTXO - XCD O2 Transmitter (without sensor), 4 to 20 mA output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted LM25, includes nylon weather protection

      SPXCDALMTXT - XCD Toxic Transmitter (without sensor), 4 to 20 mA output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted LM25, includes nylon weather protection

      SPXCDALMTXF - XCD IR & Flammable Transmitter (without sensor), 4 to 20 mA output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted LM25, includes nylon weather protection

      SPXCDASMTXO - XCD O2 Transmitter (without sensor), 4 to 20 mA output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted 316SS, includes nylon weather protection

      SPXCDASMTXT - XCD Toxic Transmitter (without sensor), 4 to 20 mA output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted 316SS, includes nylon weather protection

      SPXCDASMTXF - XCD IR & Flammable Transmitter (without sensor), 4 to 20 mA output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted 316SS, includes nylon weather protection

      SPXCDALMTXOM - XCD O2 Transmitter (without sensor), 4 to 20 mA and Modbus output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted LM25, includes nylon weather protection

      SPXCDALMTXTM - XCD Toxic Transmitter (without sensor), 4 to 20 mA and Modbus output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted LM25, includes nylon weather protection

      SPXCDALMTXFM - XCD IR & Flammable Transmitter (without sensor), 4 to 20 mA and Modbus output ATEX/IECEx/Asian approvals, 2 x M20 entries, painted LM25, includes nylon weather protection

      SPXCDASMTXOM - XCD O2 Transmitter (without sensor), 4 to 20 mA and Modbus output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted 316SS

      SPXCDASMTXTM - XCD Toxic Transmitter (without sensor), 4 to 20 mA and Modbus output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted 316SS

      SPXCDASMTXFM - XCD IR & Flammable Transmitter (without sensor), 4 to 20 mA and Modbus output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted 316SS

    • Accessories

      S3KCAL - Calibration cup (flow adapter) for Series 3000 and XNX EC toxic sensors

      SPXCDCC- Collecting cone for use with lighter-than-air gases

      SPXCDDMK - Duct mounting kit

      SPXCDMTBR - Mounting Bracket

      SPXCDSDP - Sunshade / Deluge Protection

      00780-A-0100 - Honeywell Junction Box- Bartec OTB122 With Continuity Plate 1 X 25mm 3 X 20mm Entries - ATEX Approved

      90068-A-8204 - Gassing Block 316SST. 6mm O/D Connector to Sensor and 6mm Tube Connector to Gas Bottle

      90068-C-8290 - PTFE Tubing 6mm O/D x 4mm I/D. Price per Meter

      90068-C-8291 - PTFE Tubing 8mm O/D x 6mm I/D. Price per Meter

      90068-C-8292 - Soft PVC Tubing 8mm O/D x 5mm I/D. Price per Meter

      ADU300429 - Adaptor, ATEX, Ex d e, 316SS, M20 (male) to 1/2"NPT (female)

      RDU303029 - Reducer, ATEX, Ex d e, 316SS, 3/4"NPT (male) to 1/2"NPT (female)

      PDU300400 - ATEX & CSAUS Marked, Ex d e, 316SS, IP66, M20 Blanking Plug

      PDU303000 - ATEX & CSAUS Marked, Ex d e, 316SS, IP66, 3/4" NPT Blanking Plug

      X4S-2006662 - Field Device Tag Label (Based on Drawing Number 90084-C-7013).

    • Spare Parts

      SPXCDSERVK - XCD Service Kit

      SPXCDTOOLK - XCD Service Tool Kit

      SPXCDTMK - XCD Terminals Kit

      SPXCDNPTP - Blanking Plug 3/4" NPT plug (Certified as part of Ex d enclosure)

      SPXCDM20P - Blanking Plug M20 plug (Certified as part of Ex d enclosure)

      SPXCDSRLS - Cartridge retainer with locking screw

      SPXCDWP - Weatherproof cap

      Bundle Code - Sensepoint XCD Display Modules

      Bundle Code - Sensepoint XCD Terminal Modules

    Take advantage of our web-exclusive free UK mainland* delivery offer on orders over £100 ex VAT.  See all costs for delivery below and visit our main delivery page for more information on timescales as some restrictions may apply.

    UK & Ireland Delivery Options

    UK Mainland Standard Delivery on orders under £100 ex VAT - £7.95 ex VAT*
    UK Mainland Express Delivery - £21.50 ex VAT (timescales vary – please see delivery page)
    Highlands Delivery - £25.00 ex VAT
    Channel Island Delivery - £40 ex VAT
    Northern Ireland & Republic of Ireland - £25 ex VAT
    Saturday Delivery Options – Please contact us on 0141 771 7749 for more info

    Standard delivery timescales are normally 3-5 working days, depending on stock availability.  Express delivery is normally 1-3 working days, depending on stock availability.  Although we carry an extensive stock, there may be some items that are unavailable due to quantities or otherwise.  In this case we will inform you of the status of your order and whether or not it can be fulfilled within our standard delivery timeframe. *Mainland UK delivery excludes Northern Ireland, other charges apply.

    Please visit our main delivery page for more terms and conditions or contact our Sales Team on 0141 771 7749  or [email protected] for more information. Currently, some manufacturers are facing production and delivery issues due to Brexit and custom clearance and this is affecting lead times of even some of our standard stocked items.  We're trying our best to prevent these issues from affecting orders but please be aware that there may be some delays.  We are aiming to communicate this as best and as early as possible. 

    International Delivery Options

    Delivery costs vary between countries.  Please visit our main delivery page for more information.

    You also have the option to 'Arrange Your Own Courier', whereby you organise the shipment of your own goods once they have reached our warehouse.

    ORDER CANCELLATION AND GOODS RETURN

    Should you wish to cancel an order or return unwanted goods please follow the procedures detailed below to help us ensure cancellations/returns are processed as quickly and efficiently as possible.

    Simply log on to your customer account, note the order reference number and email the full cancellation details to [email protected] or contact us on 0141 771 7749. Assuming the order has not been despatched we will cancel.

    You have the right to cancel the purchase of goods without having to give a reason at any time within the “cooling off period” of fourteen working days, beginning the day after you take delivery of your order.

    You must notify us of your cancellation in writing via email to [email protected] or to our contact address. (Details Here)

    If you are in possession of the goods you are under the duty to retain them and take reasonable care of them.

    You must send the goods back to us in their original condition to our contact address at your own cost (unless we delivered the item to you in error or the item is damaged or defective) as soon as possible once you have cancelled the contract.

    Alternatively we will collect the goods from you which will incur a charge no greater than the actual cost of arranging the collection and shipping. In this case you must make the goods available for collection. We will contact you to make further arrangements.

    We reserve the right to make a charge not exceeding our direct costs of recovering the goods if you do not return the goods or return them at our expense.

    Upon receipt of returned items in satisfactory condition we will arrange a full credit by the same method used to pay for the goods originally. Any credit due will be processed within a maximum of thirty days.

    Note: If you wish to return goods for refund or exchange after 14 days, a re-stocking fee of 20% of the full order total will apply.

    If upon receipt of goods you find them to be faulty, damaged or if you have been incorrectly supplied an item, you should notify us within 24 hours by contacting 0141 771 7749 or [email protected] and quoting your order number and contact details.

    Frontline Safety will arrange uplift of any damaged or wrongly received goods and if on inspection of goods we also find them to be damaged, faulty or incorrectly supplied, we will offer replacement goods or provide a full refund.

    We recommend you inspect all goods prior to signing for and accepting delivery. If there is any visible damage to the outer packaging, ensure goods are sign for as damaged. In instances where it isn’t possible to sign for goods as damaged, these should be signed for as unexamined.


    Note: If your goods happen to develop a fault out with the standard returns period but within supplied warranty period or if you require any additional assistance, please contact us on 0141 771 7749 or email [email protected]

    IMPORTANT INFORMATION

    All postage, handling, customs and duty charges for all returned goods are the responsibility of the customer. We recommend using a fully traceable, insured service as goods are your responsibility while in transit.

    Honeywell Sensepoint XCD - Aluminium 

    The Sensepoint XCD is an explosion-proof transmitter from Honeywell Analytics.  This provides monitoring for flammable, toxic and oxygen gas hazards in potentially explosive atmospheres.  This includes both indoor and outdoor applications. 

    The configurations listed above all have an aluminium enclosure. Stainless steel is also available.  Detectable Gases include: Oxygen, Hydrogen Sulphide, Carbon Monoxide, Hydrogen, Nitrogen Dioxide, Flammable, Methane, Propane, Carbon Dioxide

    Applications include Industrial manufacturing facilities, power plants, waste water facilities, utilities, food and beverage production, refineries and chemical plants, onshore oil and gas terminals, production platforms and exploration and drilling.

    Modifying the detectors operation can be done using the LCD screen and magnet switches.  There’s no need to open up the unit which will potentially prevent non-intrusive operation and will reduce maintenance time and costs.

    Key Features
    • User friendly and intuitive tri-colour backlit display with digits, bar graph and icons
    • Traffic light system indicates normal operation (green), faults (flashing yellow) and alarms (flashing red)
    • Can be placed on an integral mounting plate for surface mounting or can be mounted to a horizontal or vertical pipe using the optional pipe mounting bracket
    • Rated as IP66
    Specifications

    For full specification please   refer to the datasheet

    Standard Supply

    • Integral wall mounting plate, 2 x M20 cable entry (ATEX/IECEx) or 2 x   ¾”NPT conduit entries (UL/cUL),
    • 1 x M20 or 1 x ¾”NPT plug, Allen key for locking screw, weatherproof   cap, operating magnet, sensor cartridge with retainer, quick start guide and   instruction manual CD.  Default   settings, ranges and calibrations are 100% tested at the factory. Each unit   is supplied with a calibration and test certificate.

    Shipping carton dimensions:

    • L312mm (12.3”) x W223mm (8.8”) x D110mm (4.3”)
    • Approximate weight: Aluminium 2.5kg (5.5lbs)

    Certification

    •   European - ATEX II 2 GD Ex d IIC Gb T6 (Ta   -40ºC to +65ºC) T5 (Ta -40ºC to +75ºC) Ex tb IIIC T85°C Db IP66 T100ºC (Ta   -40ºC to +75ºC)
    •   International - IECEx Ex d IIC Gb T6 (Ta -40ºC   to +65ºC) T5 (Ta -40ºC to +75ºC) Ex tb IIIC T85°C Db IP66 T100ºC (Ta -40ºC to   +75ºC)
    •   China - GB Ex d IIC T4 GB3836.1&2 -2000,   PA, CCCF
    •   Korea - KTL Ex d IIC T6 (-40°C to +65°C)
    •   North America - UL/c-UL - Class I, Division 1,   Groups B, C and D, Class I, Division 2, Groups B, C & D, Class II,   Division 1, Groups E, F & G, Class II, Division 2, Groups F & G. -40ºC   to +65ºC
    •   EMC - EN50270:2006 EN6100-6-4:2007
    •   Performance - ATEX, EN60079-29-1:2007   (flammable), EN45544 (Toxic), EN50104 (Oxygen), EN50271
    •   China: PA Pattern Measurement (for transmitter   and toxic gas sensors)
    •   “CCCF” Shenyang for Flammable (fire dept   approval)
    •   CSA C22.2-152
    • Sensors

      SPXCDXSFXSS - Flammable CAT 0-100%LEL (20 to 100%LEL, 10%LEL)

      SPXCDXSRXSS - Methane IR 0-100%LEL (20 to 100%LEL, 10%LEL)

      SPXCDXSO1SS - Oxygen 25.0% v/v only

      SPXCDXSHXSS - Hydrogen Sulfide 0-50ppm (10.0 to 100.0ppm, 1ppm)

      SPXCDXSCXSS - Carbon Monoxide 0-300ppm (100 to 1000ppm, 100ppm)

      SPXCDXSNXSS - Nitrogen Dioxide 0-10ppm (10.0 to 50.0ppm, 5ppm)

      SPXCDXSG1SS - Hydrogen 0-1000ppm only

      SPXCDXSPXSS - Propane IR 0-100%LEL (20 to 100%LEL, 10%LEL)

      SPXCDXSB1SS - Carbon Dioxide IR 0-2.00% v/v only

      SPXCDXSB2SS - Carbon Dioxide IR 0-5.00% v/v only

    • Transmitters (without sensors)

      SPXCDALMTXO - XCD O2 Transmitter (without sensor), 4 to 20 mA output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted LM25, includes nylon weather protection

      SPXCDALMTXT - XCD Toxic Transmitter (without sensor), 4 to 20 mA output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted LM25, includes nylon weather protection

      SPXCDALMTXF - XCD IR & Flammable Transmitter (without sensor), 4 to 20 mA output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted LM25, includes nylon weather protection

      SPXCDASMTXO - XCD O2 Transmitter (without sensor), 4 to 20 mA output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted 316SS, includes nylon weather protection

      SPXCDASMTXT - XCD Toxic Transmitter (without sensor), 4 to 20 mA output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted 316SS, includes nylon weather protection

      SPXCDASMTXF - XCD IR & Flammable Transmitter (without sensor), 4 to 20 mA output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted 316SS, includes nylon weather protection

      SPXCDALMTXOM - XCD O2 Transmitter (without sensor), 4 to 20 mA and Modbus output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted LM25, includes nylon weather protection

      SPXCDALMTXTM - XCD Toxic Transmitter (without sensor), 4 to 20 mA and Modbus output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted LM25, includes nylon weather protection

      SPXCDALMTXFM - XCD IR & Flammable Transmitter (without sensor), 4 to 20 mA and Modbus output ATEX/IECEx/Asian approvals, 2 x M20 entries, painted LM25, includes nylon weather protection

      SPXCDASMTXOM - XCD O2 Transmitter (without sensor), 4 to 20 mA and Modbus output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted 316SS

      SPXCDASMTXTM - XCD Toxic Transmitter (without sensor), 4 to 20 mA and Modbus output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted 316SS

      SPXCDASMTXFM - XCD IR & Flammable Transmitter (without sensor), 4 to 20 mA and Modbus output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted 316SS

    • Accessories

      S3KCAL - Calibration cup (flow adapter) for Series 3000 and XNX EC toxic sensors

      SPXCDCC- Collecting cone for use with lighter-than-air gases

      SPXCDDMK - Duct mounting kit

      SPXCDMTBR - Mounting Bracket

      SPXCDSDP - Sunshade / Deluge Protection

      00780-A-0100 - Honeywell Junction Box- Bartec OTB122 With Continuity Plate 1 X 25mm 3 X 20mm Entries - ATEX Approved

      90068-A-8204 - Gassing Block 316SST. 6mm O/D Connector to Sensor and 6mm Tube Connector to Gas Bottle

      90068-C-8290 - PTFE Tubing 6mm O/D x 4mm I/D. Price per Meter

      90068-C-8291 - PTFE Tubing 8mm O/D x 6mm I/D. Price per Meter

      90068-C-8292 - Soft PVC Tubing 8mm O/D x 5mm I/D. Price per Meter

      ADU300429 - Adaptor, ATEX, Ex d e, 316SS, M20 (male) to 1/2"NPT (female)

      RDU303029 - Reducer, ATEX, Ex d e, 316SS, 3/4"NPT (male) to 1/2"NPT (female)

      PDU300400 - ATEX & CSAUS Marked, Ex d e, 316SS, IP66, M20 Blanking Plug

      PDU303000 - ATEX & CSAUS Marked, Ex d e, 316SS, IP66, 3/4" NPT Blanking Plug

      X4S-2006662 - Field Device Tag Label (Based on Drawing Number 90084-C-7013).

    • Spare Parts

      SPXCDSERVK - XCD Service Kit

      SPXCDTOOLK - XCD Service Tool Kit

      SPXCDTMK - XCD Terminals Kit

      SPXCDNPTP - Blanking Plug 3/4" NPT plug (Certified as part of Ex d enclosure)

      SPXCDM20P - Blanking Plug M20 plug (Certified as part of Ex d enclosure)

      SPXCDSRLS - Cartridge retainer with locking screw

      SPXCDWP - Weatherproof cap

      Bundle Code - Sensepoint XCD Display Modules

      Bundle Code - Sensepoint XCD Terminal Modules

    Take advantage of our web-exclusive free UK mainland* delivery offer on orders over £100 ex VAT.  See all costs for delivery below and visit our main delivery page for more information on timescales as some restrictions may apply.

    UK & Ireland Delivery Options

    UK Mainland Standard Delivery on orders under £100 ex VAT - £7.95 ex VAT*
    UK Mainland Express Delivery - £21.50 ex VAT (timescales vary – please see delivery page)
    Highlands Delivery - £25.00 ex VAT
    Channel Island Delivery - £40 ex VAT
    Northern Ireland & Republic of Ireland - £25 ex VAT
    Saturday Delivery Options – Please contact us on 0141 771 7749 for more info

    Standard delivery timescales are normally 3-5 working days, depending on stock availability.  Express delivery is normally 1-3 working days, depending on stock availability.  Although we carry an extensive stock, there may be some items that are unavailable due to quantities or otherwise.  In this case we will inform you of the status of your order and whether or not it can be fulfilled within our standard delivery timeframe. *Mainland UK delivery excludes Northern Ireland, other charges apply.

    Please visit our main delivery page for more terms and conditions or contact our Sales Team on 0141 771 7749  or [email protected] for more information. Currently, some manufacturers are facing production and delivery issues due to Brexit and custom clearance and this is affecting lead times of even some of our standard stocked items.  We're trying our best to prevent these issues from affecting orders but please be aware that there may be some delays.  We are aiming to communicate this as best and as early as possible. 

    International Delivery Options

    Delivery costs vary between countries.  Please visit our main delivery page for more information.

    You also have the option to 'Arrange Your Own Courier', whereby you organise the shipment of your own goods once they have reached our warehouse.

    ORDER CANCELLATION AND GOODS RETURN

    Should you wish to cancel an order or return unwanted goods please follow the procedures detailed below to help us ensure cancellations/returns are processed as quickly and efficiently as possible.

    Simply log on to your customer account, note the order reference number and email the full cancellation details to [email protected] or contact us on 0141 771 7749. Assuming the order has not been despatched we will cancel.

    You have the right to cancel the purchase of goods without having to give a reason at any time within the “cooling off period” of fourteen working days, beginning the day after you take delivery of your order.

    You must notify us of your cancellation in writing via email to [email protected] or to our contact address. (Details Here)

    If you are in possession of the goods you are under the duty to retain them and take reasonable care of them.

    You must send the goods back to us in their original condition to our contact address at your own cost (unless we delivered the item to you in error or the item is damaged or defective) as soon as possible once you have cancelled the contract.

    Alternatively we will collect the goods from you which will incur a charge no greater than the actual cost of arranging the collection and shipping. In this case you must make the goods available for collection. We will contact you to make further arrangements.

    We reserve the right to make a charge not exceeding our direct costs of recovering the goods if you do not return the goods or return them at our expense.

    Upon receipt of returned items in satisfactory condition we will arrange a full credit by the same method used to pay for the goods originally. Any credit due will be processed within a maximum of thirty days.

    Note: If you wish to return goods for refund or exchange after 14 days, a re-stocking fee of 20% of the full order total will apply.

    If upon receipt of goods you find them to be faulty, damaged or if you have been incorrectly supplied an item, you should notify us within 24 hours by contacting 0141 771 7749 or [email protected] and quoting your order number and contact details.

    Frontline Safety will arrange uplift of any damaged or wrongly received goods and if on inspection of goods we also find them to be damaged, faulty or incorrectly supplied, we will offer replacement goods or provide a full refund.

    We recommend you inspect all goods prior to signing for and accepting delivery. If there is any visible damage to the outer packaging, ensure goods are sign for as damaged. In instances where it isn’t possible to sign for goods as damaged, these should be signed for as unexamined.


    Note: If your goods happen to develop a fault out with the standard returns period but within supplied warranty period or if you require any additional assistance, please contact us on 0141 771 7749 or email [email protected]

    IMPORTANT INFORMATION

    All postage, handling, customs and duty charges for all returned goods are the responsibility of the customer. We recommend using a fully traceable, insured service as goods are your responsibility while in transit.