Sensepoint XCL White Bluetooth with Modbus and Relay
The Sensepoint XCL white Bluetooth (with Modbus and Relay) has been manufactured by Honeywell that allows users to install, commission and maintain the device all from a Sensepoint smartphone application. The device is a simple to use fixed point gas leak detection system made to meet the needs of commercial and light industrial applications. This configuration comes with both a modbus and relay giving the user a flexible device in terms of output.
Applications of this system includes manufacturing facilities and factories, boiler rooms and parking areas. For more information on the system’s applications please view the datasheets provided. Alternatively, you can get in touch with us. Users do not have to worry about being an expert in order to use the Sensepoint XCL Bluetooth system as it’s designed to be set up easily from their own smartphone using the dedicated application.
Using the smartphone application users can not only generate reports that are important to them, but they can also share them directly from their device. This would save users time when trying to generate various reports. The design of the Sensepoint XCL White Bluetooth with modbus and relay allows it to blend in with its environment and it uses a mechanical housing which is basic but robust.
The use of relays allows the system to be controlled locally instead of having to rely on a controller and the modbus function means that the system can send data to other systems over serial lines, allowing the Sensepoint to communicate with other devices.
Available options include;
Part Number |
Description |
SPLCF6BMRWXNZZ |
Sensepoint XCL, Modbus , Relay, Catalytic Sensor 0 to 100% LEL(CH4 calibrated), BLE enabled, White |
SPLCO1BMRWXNZZ |
Sensepoint XCL, Modbus , Relay, Oxygen 0 to 25% vol , BLE enabled, White |
SPLCC1BMRWXNZZ |
Sensepoint XCL, Modbus , Relay, CO 300ppm (adjustable 50-1000ppm) , BLE enabled, White |
SPLCH1BMRWXNZZ |
Sensepoint XCL, Modbus , Relay, H2S 50.0ppm , BLE enabled, White |
SPLCH2BMRWXNZZ |
Sensepoint XCL, Modbus , Relay, H2S(H) 100ppm (adjustable 50-200ppm) , BLE enabled, White |
SPLCG1BMRWXNZZ |
Sensepoint XCL, Modbus , Relay, H2 1000ppm (fixed), BLE enabled, White |
SPLCN1BMRWXNZZ |
Sensepoint XCL, Modbus , Relay, NO2 20ppm (adjustable 5-50ppm), BLE enabled, White |
SPLCA1BMRWXNZZ |
Sensepoint XCL, Modbus ,Relay, NH3(L) 100ppm (adjustable 50-200ppm), BLE enabled, White |
SPLCB3BMRWXNZZ |
Sensepoint XCL, Modbus , Relay, CO2 5000 ppm (adjustable 1000 -5000 ppm), BLE enabled, White |
SPLCB4BMRWXNZZ |
Sensepoint XCL, Modbus , Relay, Co2 5 % v/v (adjustable 1.0 % v/v -5% v/v), BLE enabled, White |
- IP65 rated
- User friendly due to the system having LED indicator for status
- System can be managed using a smartphone app
- Easy to use and set up – no expertise required
Please refer to the datasheet for more information |
|
Dimensions |
113 x 113 x 59 mm ( 4.4 x 4.4 x 2.3 in ) |
Weight |
500 g (1.1 lb) |
Casing material |
Polycarbonate (White) |
Lifetime |
10 years (excludes sensor) |
Connection type |
Pluggable rising clamp style, 0.5 to
|
Available sensors: |
|
Power supply (Nominal DC Input Voltage) |
24 V DC† |
Nominal AC Input Voltage |
24 V AC‡, 50/60 Hz |
Maximum Inrush Current |
850 mA |
Output (Analog Output) |
0 to 22 mA |
Digital Output |
Modbus RTU |
Relay Output |
2 relays rated at 24 V DC / 240 V AC, 5 A |
Maximum Power Consumption (mA Versions) |
< 1.2 W (toxic), < 1.7 W (flammable and CO2) |
Modbus Versions |
< 0.7 W (toxic), < 1.2 W (flammable and CO2) |
Relay Versions |
Additional 0.6 W total |
Connection Type |
Pluggable rising clamp style, 0.5 to
|
User Interface Visual Indicator |
|
Wireless Interface |
Bluetooth 4.0 (Bluetooth Low Energy). Dedicated mobile app, enabling wireless configuration and maintenance. Connect up to 10 m away (mobile device dependent). Use a compatible smartphone or other mobile device running Android 4.3 or above. |
Operating Temperature |
−20 to 50°C (−4 to 122 °F) 0 to 30°C |
Storage Temperature |
(32 to 86 °F) |
Humidity |
15 to 90% RH (non-condensing) |
Atmospheric Pressure |
90 to 110 kPa |
Approvals Electrical Safety |
|
EMC |
EN 50270 |
Radio |
RED, FCC |
Other |
UL2075 (CO and CH4), AS 1668.2 |
- † mA versions: 11 to 32 VDC, Modbus versions: 9 to 32 VDC
- ‡ All versions: 20 to 27 VAC