    Series 3000 MK II Instrument

    Series 3000 MkII Instrument

    The Series 3000 MkII Instrument provides comprehensive monitoring of oxygen and toxic gas hazards in potentially explosive atmospheres. The Series 3000 MkII variation is mainly for use in Zone 1 applications. The optional remote mounting kit allows the device to also be used in a Zone 0 location. This device is held in a flameproof housing giving it protection for explosive environments. The MkII has a sensor connection that is intrinsically safe.

    Examples of applications in which the MkII device may be used in include drilling and exploration platforms, wastewater facilities, power plants, utilities, production platforms, onshore oil and gas terminals and refineries and chemical plants. This instrument provides reliable detection thanks to the electrochemical sensing technology and the use of Surecell™ electrochemical cells along with a ‘reflex’ patented technology.

    There are benefits to using the MK II.  This includes the ability to mount the device with an optional horizontal or vertical pipe-mounting bracket, the sensor is able to auto-configure the transmitter and the device has a non-intrusive arrangement. The Series MkII has a range of accessories that can be used to enhance the device. These include remote sensor mounting kit, duct mounting kit (for H2, CO and H2S only), collecting cone and calibration cup to apply test gas. Please get in touch with us for more information on the accessories range for the system.

    Available options include:

    S3KAL2

    ATEX/IECEx approved Series 3000 MkII toxic and oxygen transmitter, Aluminium LM25 and 2 x M20 entries

    S3KAS2

    ATEX/IECEx approved Series 3000 MkII toxic and oxygen transmitter, Stainless Steel 316 and 2 x M20 entries

    Key Features
    • Compliant with regulation
    • Reliable detection and life-long sensing elements
    • Reduced cost of maintenance
    • IP66 (EN 60529), NEMA 4X
    • Optional range of accessories available
    • Ability to retrofit in place of series 2000
    • MkIII is also available but requires a separate IS barrier for Zone 0 applications
    Specifications

    Please see datasheet for more information

    Weight

    • Aluminium alloy LM25: 1.7kg (3.75lbs.)
    • Stainless Steel 316: 3.7kg (8.16lbs.)

    Material

    • Transmitter: Epoxy painted aluminium alloy
    • LM25 or 316 Stainless Steel, Sensor: 316
    • Stainless Steel with PTFE filter

    Dimensions

    164mm x 201mm x 99mm (6.4” x 7.9” x 3.9”)

    Operating temperature

    ATEX/IECEX: -20°C to +55°C (-4°F to +131°F)

    Connections and Power

    • 2-wire loop powered
    • 17Vdc (±10%) to 32Vdc (max)
    • 22mA max. over range

    Mounting

    Remote sensor mounting kit (optional accessory)

    Cable entries

    • 2 x M20 cable entries (ATEX/IECEx version) or
    • 2 x ¾”NPT conduit entries (UL/c-UL versions)

    Approvals

    Transmitter:

    • UL/c-UL: Class I, Div. 1 & 2, Groups B, C & D;
    • Class II, Div. 1 Groups E, F & G, Class II, Div. 2, Groups
    • F & G; Class I, Zone 1, Group IIB + H2 Hazardous
    • Locations
    • ATEX: II 2 (1) GD Ex d [ia IIC Ga] IIB + H2 T4 Gb
    • Ex t [ia IIIC Da] IIIB T135°C Db
    • IECEx: Ex d [ia IIC Ga] IIB + H2 T4 Gb Ex t [ia IIIC Da]
    • IIIB T135°C Db 

    Remote Sensor Accessory:

    • UL/c-UL: Class I, Division 1, Groups A, B, C and D
    • Class II, Divisions 1 and 2, Groups E, F and G
    • Class 1, Zone 0, Group IIC; Class II, Zone 20
    • ATEX: II 1G D Ex ia IIC T4 Ga Ex ia IIIC T135°C Da
    • IECEx: Ex ia IIC T4 Ga Ex ia IIIC T135°C Da

    •  CE compliant in accordance with: ATEX Directive 94/9/EC, EMC Directive 2004/108/EC, EN 50270

    Sensor

    Please see the datasheet for information

    Recommended Cable

    • 2-wire with screen (90% coverage) or conduit
    • 0.5mm2  (20AWG) to 2.0mm2  (14AWG)

    Signal

    • 0-100% FSD 4-20mA
    • Fault = 3mA
    • Calibration due selectable off or 3mA
    • Max. over range 22mA
    • Inhibit (toxic sensors) = Selectable 3mA or 4mA
    • Inhibit (Oxygen sensors) = Selectable 3mA or 17.4mA
    • Sensors

      S3KXSO1SS - Oxygen 0-25%v/v

      S3KXSC1SS - Carbon Monoxide 0-300ppm (100 to 500ppm, 100ppm)

      S3KXSC2SS - Carbon Monoxide 0-300ppm (100 to 999ppm, 100ppm)

      S3KXSH1SS - Hydrogen Sulphide 0-15ppm (10 to 50ppm, 1ppm)

      S3KXSH2SS - Hydrogen Sulphide 0-100ppm (50 to 500ppm, 10ppm)

      S3KXSL1SS - Chlorine 0-5.0ppm (5.0 to 20.0ppm, 5.0ppm)

      S3KXSS1SS - Sulphur Dioxide 0-15.0ppm (5.0 to 20.0ppm, 5.0ppm)

      S3KXSX1SS - Chlorine Dioxide 0-1.00ppm

      S3KXSM1SS - Nitrogen Monoxide 0-100ppm

      S3KXSN1SS - Nitrogen Dioxide 0-10.0ppm (5.0 to 50.0ppm, 5.0ppm)

      S3KXSG1SS - Hydrogen 0-1000ppm

      S3KXSG2SS - Hydrogen 0-10,000ppm

      S3KXSR1SS - Hydrogen Chloride 0-10ppm (10.0 to 20.0ppm, 1.0ppm)

      S3KXSY1SS - Hydrogen Cyanide 0-30.0ppm

      S3KXSF1SS - Hydrogen Fluoride 0-12.0ppm (Fixed Scale)

      S3KXSA1SS - Ammonia 0-200ppm (50 to 200ppm, 50ppm)

      S3KXSA2SS - Ammonia 0-1000ppm (200 to 1000ppm, 50ppm)

      S3KXSP1SS - Phosphine (PH3) 0-1.2ppm (Fixed Scale)

      S3KXSU1SS - Fluorine (F2) 4ppm

      S3KXSE1SS  - Ethylene Oxide (ETO), 25.0ppm (20.0 to 50.0ppm)

      S3KXSZ1SS - Ozone (O3) 0.400ppm

    • Accessories

      SPXCDMTBR - Mounting Bracket

      SPXCDSDP - Sunshade / Deluge Protection

      S3KCAL - Calibration cup (flow adapter) for Series 3000 and XNX EC toxic sensors

      S3KCC - Collecting cone (for Series 3000 & XNX EC toxic sensors)

      S3KDMK - Duct mounting kit for Series 3000 and XNX EC toxic sensors

      S3KWP - Weatherproof housing with bump test port for use with Series 3000 and XNX EC toxic

      S3KRMK - Remote mounting kit for Series 3000 and XNX EC toxic sensors

      S3KRMK45 - Remote mounting kit for Series 3000 and XNX EC toxic sensors

      SGPTPRMTL1 - Single channel zener barrier MTL7728+

      SGPTPRMTL2 - 2 channel zener barrier MTL7787+

      SGPTPRMTL3 - Galvanic Isolator MTL 5042

      SGPTPRPFG1 - Galvanic Isolator P&F KFD2-STC4-EX1

      90068-A-8204 - Gassing Block 316SST. 6mm O/D Connector to Sensor and 6mm Tube Connector to Gas Bottle

      90068-C-8290 - PTFE Tubing 6mm O/D x 4mm I/D. Price per Meter

      90068-C-8291 - PTFE Tubing 8mm O/D x 6mm I/D. Price per Meter

      90068-C-8292 - Soft PVC Tubing 8mm O/D x 5mm I/D. Price per Meter

      ADU300429 - Adaptor, ATEX, Ex d e, 316SS, M20 (male) to 1/2"NPT (female)

      RDU303029 - Reducer, ATEX, Ex d e, 316SS, 3/4"NPT (male) to 1/2"NPT (female)

      PDU300400 - ATEX & CSAUS Marked, Ex d e, 316SS, IP66, M20 Blanking Plug

      PDU303000 - ATEX & CSAUS Marked, Ex d e, 316SS, IP66, 3/4" NPT Blanking Plug

      X4S-2006662 - Field Device Tag Label

    • Cell Exchange Kits

      S3KO1SS - Oxygen 0-25%v/v

      S3KC1SS - Carbon Monoxide 0-300ppm (100 to 999ppm, 100ppm)

      S3KH1SS - Hydrogen Sulphide 0-15ppm (10 to 50ppm, 1ppm)

      S3KH2SS - Hydrogen Sulphide 0-100ppm (50 to 500ppm, 10ppm)

      S3KL1SS - Chlorine 0-5.0ppm (5.0 to 20.0ppm, 5.0ppm)

      S3KS1SS - Sulphur Dioxide 0-15.0ppm (5.0 to 20.0ppm, 5.0ppm)

      S3KX1SS - Chlorine Dioxide 0-1.00ppm

      S3KM1SS - Nitrogen Monoxide 0-100ppm

      S3KN1SS - Nitrogen Dioxide 0-10.0ppm (5.0 to 50.0ppm, 5.0ppm)

      S3KG1SS - Hydrogen 0-1000ppm

      S3KG2SS - Hydrogen 0-10,000ppm

      S3KY1SS - Hydrogen Cyanide 0-30.0ppm

      S3KF1SS - Hydrogen Fluoride 0-12.0ppm (Fixed Scale)

      S3KR1SS - Hydrogen Chloride 0-10ppm (10.0 to 20.0ppm, 1.0ppm)

      S3KA1SS - Ammonia 0-200ppm (50 to 200ppm, 50ppm)

      S3KA2SS - Ammonia 0-1000ppm (200 to 1000ppm, 50ppm)

      S3KP1SS - Phosphine (PH3), 1.2ppm (Fixed Scale)

      S3KU1SS - Fluorine 4ppm

      S3KE1SS - Ethylene Oxide (ETO), 25.0ppm (20.0 to 50.0ppm)

      S3KZ1SS - Ozone 0.400ppm

    • Spares

      S3KDM - Replacement Display Module

      S3KTM - Replacement Terminal Module

      S3KDM3 - Mk III Replacement Display Module

      S3KTM3 - Mk III Replacement Terminal Module

      S3KWP - Weatherproof Housing with bump test port for use with Series 3000 and XNX EC toxic

      SPXCDMAG - Magnet

      SPXCDHWES - Hex wrench for earth screw

      SPXCDEBS - Earth Bracket and Screws

      S3KM20P - M20 Blanking Plug

      S3KNPTP - 3/4"NPT Blanking Plug

    Take advantage of our web-exclusive free UK mainland* delivery offer on orders over £100 ex VAT.  See all costs for delivery below and visit our main delivery page for more information on timescales as some restrictions may apply.

    UK & Ireland Delivery Options

    UK Mainland Standard Delivery on orders under £100 ex VAT - £7.95 ex VAT*
    UK Mainland Express Delivery - £21.50 ex VAT (timescales vary – please see delivery page)
    Highlands Delivery - £25.00 ex VAT
    Channel Island Delivery - £40 ex VAT
    Northern Ireland & Republic of Ireland - £25 ex VAT
    Saturday Delivery Options – Please contact us on 0141 771 7749 for more info

    Standard delivery timescales are normally 3-5 working days, depending on stock availability.  Express delivery is normally 1-3 working days, depending on stock availability.  Although we carry an extensive stock, there may be some items that are unavailable due to quantities or otherwise.  In this case we will inform you of the status of your order and whether or not it can be fulfilled within our standard delivery timeframe. *Mainland UK delivery excludes Northern Ireland, other charges apply.

    Please visit our main delivery page for more terms and conditions or contact our Sales Team on 0141 771 7749  or [email protected] for more information. Currently, some manufacturers are facing production and delivery issues due to Brexit and custom clearance and this is affecting lead times of even some of our standard stocked items.  We're trying our best to prevent these issues from affecting orders but please be aware that there may be some delays.  We are aiming to communicate this as best and as early as possible. 

    International Delivery Options

    Delivery costs vary between countries.  Please visit our main delivery page for more information.

    You also have the option to 'Arrange Your Own Courier', whereby you organise the shipment of your own goods once they have reached our warehouse.

    ORDER CANCELLATION AND GOODS RETURN

    Should you wish to cancel an order or return unwanted goods please follow the procedures detailed below to help us ensure cancellations/returns are processed as quickly and efficiently as possible.

    Simply log on to your customer account, note the order reference number and email the full cancellation details to [email protected] or contact us on 0141 771 7749. Assuming the order has not been despatched we will cancel.

    You have the right to cancel the purchase of goods without having to give a reason at any time within the “cooling off period” of fourteen working days, beginning the day after you take delivery of your order.

    You must notify us of your cancellation in writing via email to [email protected] or to our contact address. (Details Here)

    If you are in possession of the goods you are under the duty to retain them and take reasonable care of them.

    You must send the goods back to us in their original condition to our contact address at your own cost (unless we delivered the item to you in error or the item is damaged or defective) as soon as possible once you have cancelled the contract.

    Alternatively we will collect the goods from you which will incur a charge no greater than the actual cost of arranging the collection and shipping. In this case you must make the goods available for collection. We will contact you to make further arrangements.

    We reserve the right to make a charge not exceeding our direct costs of recovering the goods if you do not return the goods or return them at our expense.

    Upon receipt of returned items in satisfactory condition we will arrange a full credit by the same method used to pay for the goods originally. Any credit due will be processed within a maximum of thirty days.

    Note: If you wish to return goods for refund or exchange after 14 days, a re-stocking fee of 20% of the full order total will apply.

    If upon receipt of goods you find them to be faulty, damaged or if you have been incorrectly supplied an item, you should notify us within 24 hours by contacting 0141 771 7749 or [email protected] and quoting your order number and contact details.

    Frontline Safety will arrange uplift of any damaged or wrongly received goods and if on inspection of goods we also find them to be damaged, faulty or incorrectly supplied, we will offer replacement goods or provide a full refund.

    We recommend you inspect all goods prior to signing for and accepting delivery. If there is any visible damage to the outer packaging, ensure goods are sign for as damaged. In instances where it isn’t possible to sign for goods as damaged, these should be signed for as unexamined.


    Note: If your goods happen to develop a fault out with the standard returns period but within supplied warranty period or if you require any additional assistance, please contact us on 0141 771 7749 or email [email protected]

    IMPORTANT INFORMATION

    All postage, handling, customs and duty charges for all returned goods are the responsibility of the customer. We recommend using a fully traceable, insured service as goods are your responsibility while in transit.

    Series 3000 MkII Instrument

    The Series 3000 MkII Instrument provides comprehensive monitoring of oxygen and toxic gas hazards in potentially explosive atmospheres. The Series 3000 MkII variation is mainly for use in Zone 1 applications. The optional remote mounting kit allows the device to also be used in a Zone 0 location. This device is held in a flameproof housing giving it protection for explosive environments. The MkII has a sensor connection that is intrinsically safe.

    Examples of applications in which the MkII device may be used in include drilling and exploration platforms, wastewater facilities, power plants, utilities, production platforms, onshore oil and gas terminals and refineries and chemical plants. This instrument provides reliable detection thanks to the electrochemical sensing technology and the use of Surecell™ electrochemical cells along with a ‘reflex’ patented technology.

    There are benefits to using the MK II.  This includes the ability to mount the device with an optional horizontal or vertical pipe-mounting bracket, the sensor is able to auto-configure the transmitter and the device has a non-intrusive arrangement. The Series MkII has a range of accessories that can be used to enhance the device. These include remote sensor mounting kit, duct mounting kit (for H2, CO and H2S only), collecting cone and calibration cup to apply test gas. Please get in touch with us for more information on the accessories range for the system.

    Available options include:

    S3KAL2

    ATEX/IECEx approved Series 3000 MkII toxic and oxygen transmitter, Aluminium LM25 and 2 x M20 entries

    S3KAS2

    ATEX/IECEx approved Series 3000 MkII toxic and oxygen transmitter, Stainless Steel 316 and 2 x M20 entries

    Key Features
    • Compliant with regulation
    • Reliable detection and life-long sensing elements
    • Reduced cost of maintenance
    • IP66 (EN 60529), NEMA 4X
    • Optional range of accessories available
    • Ability to retrofit in place of series 2000
    • MkIII is also available but requires a separate IS barrier for Zone 0 applications
    Specifications

    Please see datasheet for more information

    Weight

    • Aluminium alloy LM25: 1.7kg (3.75lbs.)
    • Stainless Steel 316: 3.7kg (8.16lbs.)

    Material

    • Transmitter: Epoxy painted aluminium alloy
    • LM25 or 316 Stainless Steel, Sensor: 316
    • Stainless Steel with PTFE filter

    Dimensions

    164mm x 201mm x 99mm (6.4” x 7.9” x 3.9”)

    Operating temperature

    ATEX/IECEX: -20°C to +55°C (-4°F to +131°F)

    Connections and Power

    • 2-wire loop powered
    • 17Vdc (±10%) to 32Vdc (max)
    • 22mA max. over range

    Mounting

    Remote sensor mounting kit (optional accessory)

    Cable entries

    • 2 x M20 cable entries (ATEX/IECEx version) or
    • 2 x ¾”NPT conduit entries (UL/c-UL versions)

    Approvals

    Transmitter:

    • UL/c-UL: Class I, Div. 1 & 2, Groups B, C & D;
    • Class II, Div. 1 Groups E, F & G, Class II, Div. 2, Groups
    • F & G; Class I, Zone 1, Group IIB + H2 Hazardous
    • Locations
    • ATEX: II 2 (1) GD Ex d [ia IIC Ga] IIB + H2 T4 Gb
    • Ex t [ia IIIC Da] IIIB T135°C Db
    • IECEx: Ex d [ia IIC Ga] IIB + H2 T4 Gb Ex t [ia IIIC Da]
    • IIIB T135°C Db 

    Remote Sensor Accessory:

    • UL/c-UL: Class I, Division 1, Groups A, B, C and D
    • Class II, Divisions 1 and 2, Groups E, F and G
    • Class 1, Zone 0, Group IIC; Class II, Zone 20
    • ATEX: II 1G D Ex ia IIC T4 Ga Ex ia IIIC T135°C Da
    • IECEx: Ex ia IIC T4 Ga Ex ia IIIC T135°C Da

    •  CE compliant in accordance with: ATEX Directive 94/9/EC, EMC Directive 2004/108/EC, EN 50270

    Sensor

    Please see the datasheet for information

    Recommended Cable

    • 2-wire with screen (90% coverage) or conduit
    • 0.5mm2  (20AWG) to 2.0mm2  (14AWG)

    Signal

    • 0-100% FSD 4-20mA
    • Fault = 3mA
    • Calibration due selectable off or 3mA
    • Max. over range 22mA
    • Inhibit (toxic sensors) = Selectable 3mA or 4mA
    • Inhibit (Oxygen sensors) = Selectable 3mA or 17.4mA
    • Sensors

      S3KXSO1SS - Oxygen 0-25%v/v

      S3KXSC1SS - Carbon Monoxide 0-300ppm (100 to 500ppm, 100ppm)

      S3KXSC2SS - Carbon Monoxide 0-300ppm (100 to 999ppm, 100ppm)

      S3KXSH1SS - Hydrogen Sulphide 0-15ppm (10 to 50ppm, 1ppm)

      S3KXSH2SS - Hydrogen Sulphide 0-100ppm (50 to 500ppm, 10ppm)

      S3KXSL1SS - Chlorine 0-5.0ppm (5.0 to 20.0ppm, 5.0ppm)

      S3KXSS1SS - Sulphur Dioxide 0-15.0ppm (5.0 to 20.0ppm, 5.0ppm)

      S3KXSX1SS - Chlorine Dioxide 0-1.00ppm

      S3KXSM1SS - Nitrogen Monoxide 0-100ppm

      S3KXSN1SS - Nitrogen Dioxide 0-10.0ppm (5.0 to 50.0ppm, 5.0ppm)

      S3KXSG1SS - Hydrogen 0-1000ppm

      S3KXSG2SS - Hydrogen 0-10,000ppm

      S3KXSR1SS - Hydrogen Chloride 0-10ppm (10.0 to 20.0ppm, 1.0ppm)

      S3KXSY1SS - Hydrogen Cyanide 0-30.0ppm

      S3KXSF1SS - Hydrogen Fluoride 0-12.0ppm (Fixed Scale)

      S3KXSA1SS - Ammonia 0-200ppm (50 to 200ppm, 50ppm)

      S3KXSA2SS - Ammonia 0-1000ppm (200 to 1000ppm, 50ppm)

      S3KXSP1SS - Phosphine (PH3) 0-1.2ppm (Fixed Scale)

      S3KXSU1SS - Fluorine (F2) 4ppm

      S3KXSE1SS  - Ethylene Oxide (ETO), 25.0ppm (20.0 to 50.0ppm)

      S3KXSZ1SS - Ozone (O3) 0.400ppm

    • Accessories

      SPXCDMTBR - Mounting Bracket

      SPXCDSDP - Sunshade / Deluge Protection

      S3KCAL - Calibration cup (flow adapter) for Series 3000 and XNX EC toxic sensors

      S3KCC - Collecting cone (for Series 3000 & XNX EC toxic sensors)

      S3KDMK - Duct mounting kit for Series 3000 and XNX EC toxic sensors

      S3KWP - Weatherproof housing with bump test port for use with Series 3000 and XNX EC toxic

      S3KRMK - Remote mounting kit for Series 3000 and XNX EC toxic sensors

      S3KRMK45 - Remote mounting kit for Series 3000 and XNX EC toxic sensors

      SGPTPRMTL1 - Single channel zener barrier MTL7728+

      SGPTPRMTL2 - 2 channel zener barrier MTL7787+

      SGPTPRMTL3 - Galvanic Isolator MTL 5042

      SGPTPRPFG1 - Galvanic Isolator P&F KFD2-STC4-EX1

      90068-A-8204 - Gassing Block 316SST. 6mm O/D Connector to Sensor and 6mm Tube Connector to Gas Bottle

      90068-C-8290 - PTFE Tubing 6mm O/D x 4mm I/D. Price per Meter

      90068-C-8291 - PTFE Tubing 8mm O/D x 6mm I/D. Price per Meter

      90068-C-8292 - Soft PVC Tubing 8mm O/D x 5mm I/D. Price per Meter

      ADU300429 - Adaptor, ATEX, Ex d e, 316SS, M20 (male) to 1/2"NPT (female)

      RDU303029 - Reducer, ATEX, Ex d e, 316SS, 3/4"NPT (male) to 1/2"NPT (female)

      PDU300400 - ATEX & CSAUS Marked, Ex d e, 316SS, IP66, M20 Blanking Plug

      PDU303000 - ATEX & CSAUS Marked, Ex d e, 316SS, IP66, 3/4" NPT Blanking Plug

      X4S-2006662 - Field Device Tag Label

    • Cell Exchange Kits

      S3KO1SS - Oxygen 0-25%v/v

      S3KC1SS - Carbon Monoxide 0-300ppm (100 to 999ppm, 100ppm)

      S3KH1SS - Hydrogen Sulphide 0-15ppm (10 to 50ppm, 1ppm)

      S3KH2SS - Hydrogen Sulphide 0-100ppm (50 to 500ppm, 10ppm)

      S3KL1SS - Chlorine 0-5.0ppm (5.0 to 20.0ppm, 5.0ppm)

      S3KS1SS - Sulphur Dioxide 0-15.0ppm (5.0 to 20.0ppm, 5.0ppm)

      S3KX1SS - Chlorine Dioxide 0-1.00ppm

      S3KM1SS - Nitrogen Monoxide 0-100ppm

      S3KN1SS - Nitrogen Dioxide 0-10.0ppm (5.0 to 50.0ppm, 5.0ppm)

      S3KG1SS - Hydrogen 0-1000ppm

      S3KG2SS - Hydrogen 0-10,000ppm

      S3KY1SS - Hydrogen Cyanide 0-30.0ppm

      S3KF1SS - Hydrogen Fluoride 0-12.0ppm (Fixed Scale)

      S3KR1SS - Hydrogen Chloride 0-10ppm (10.0 to 20.0ppm, 1.0ppm)

      S3KA1SS - Ammonia 0-200ppm (50 to 200ppm, 50ppm)

      S3KA2SS - Ammonia 0-1000ppm (200 to 1000ppm, 50ppm)

      S3KP1SS - Phosphine (PH3), 1.2ppm (Fixed Scale)

      S3KU1SS - Fluorine 4ppm

      S3KE1SS - Ethylene Oxide (ETO), 25.0ppm (20.0 to 50.0ppm)

      S3KZ1SS - Ozone 0.400ppm

    • Spares

      S3KDM - Replacement Display Module

      S3KTM - Replacement Terminal Module

      S3KDM3 - Mk III Replacement Display Module

      S3KTM3 - Mk III Replacement Terminal Module

      S3KWP - Weatherproof Housing with bump test port for use with Series 3000 and XNX EC toxic

      SPXCDMAG - Magnet

      SPXCDHWES - Hex wrench for earth screw

      SPXCDEBS - Earth Bracket and Screws

      S3KM20P - M20 Blanking Plug

      S3KNPTP - 3/4"NPT Blanking Plug

    Take advantage of our web-exclusive free UK mainland* delivery offer on orders over £100 ex VAT.  See all costs for delivery below and visit our main delivery page for more information on timescales as some restrictions may apply.

    UK & Ireland Delivery Options

    UK Mainland Standard Delivery on orders under £100 ex VAT - £7.95 ex VAT*
    UK Mainland Express Delivery - £21.50 ex VAT (timescales vary – please see delivery page)
    Highlands Delivery - £25.00 ex VAT
    Channel Island Delivery - £40 ex VAT
    Northern Ireland & Republic of Ireland - £25 ex VAT
    Saturday Delivery Options – Please contact us on 0141 771 7749 for more info

    Standard delivery timescales are normally 3-5 working days, depending on stock availability.  Express delivery is normally 1-3 working days, depending on stock availability.  Although we carry an extensive stock, there may be some items that are unavailable due to quantities or otherwise.  In this case we will inform you of the status of your order and whether or not it can be fulfilled within our standard delivery timeframe. *Mainland UK delivery excludes Northern Ireland, other charges apply.

    Please visit our main delivery page for more terms and conditions or contact our Sales Team on 0141 771 7749  or [email protected] for more information. Currently, some manufacturers are facing production and delivery issues due to Brexit and custom clearance and this is affecting lead times of even some of our standard stocked items.  We're trying our best to prevent these issues from affecting orders but please be aware that there may be some delays.  We are aiming to communicate this as best and as early as possible. 

    International Delivery Options

    Delivery costs vary between countries.  Please visit our main delivery page for more information.

    You also have the option to 'Arrange Your Own Courier', whereby you organise the shipment of your own goods once they have reached our warehouse.

    ORDER CANCELLATION AND GOODS RETURN

    Should you wish to cancel an order or return unwanted goods please follow the procedures detailed below to help us ensure cancellations/returns are processed as quickly and efficiently as possible.

    Simply log on to your customer account, note the order reference number and email the full cancellation details to [email protected] or contact us on 0141 771 7749. Assuming the order has not been despatched we will cancel.

    You have the right to cancel the purchase of goods without having to give a reason at any time within the “cooling off period” of fourteen working days, beginning the day after you take delivery of your order.

    You must notify us of your cancellation in writing via email to [email protected] or to our contact address. (Details Here)

    If you are in possession of the goods you are under the duty to retain them and take reasonable care of them.

    You must send the goods back to us in their original condition to our contact address at your own cost (unless we delivered the item to you in error or the item is damaged or defective) as soon as possible once you have cancelled the contract.

    Alternatively we will collect the goods from you which will incur a charge no greater than the actual cost of arranging the collection and shipping. In this case you must make the goods available for collection. We will contact you to make further arrangements.

    We reserve the right to make a charge not exceeding our direct costs of recovering the goods if you do not return the goods or return them at our expense.

    Upon receipt of returned items in satisfactory condition we will arrange a full credit by the same method used to pay for the goods originally. Any credit due will be processed within a maximum of thirty days.

    Note: If you wish to return goods for refund or exchange after 14 days, a re-stocking fee of 20% of the full order total will apply.

    If upon receipt of goods you find them to be faulty, damaged or if you have been incorrectly supplied an item, you should notify us within 24 hours by contacting 0141 771 7749 or [email protected] and quoting your order number and contact details.

    Frontline Safety will arrange uplift of any damaged or wrongly received goods and if on inspection of goods we also find them to be damaged, faulty or incorrectly supplied, we will offer replacement goods or provide a full refund.

    We recommend you inspect all goods prior to signing for and accepting delivery. If there is any visible damage to the outer packaging, ensure goods are sign for as damaged. In instances where it isn’t possible to sign for goods as damaged, these should be signed for as unexamined.


    Note: If your goods happen to develop a fault out with the standard returns period but within supplied warranty period or if you require any additional assistance, please contact us on 0141 771 7749 or email [email protected]

    IMPORTANT INFORMATION

    All postage, handling, customs and duty charges for all returned goods are the responsibility of the customer. We recommend using a fully traceable, insured service as goods are your responsibility while in transit.