large image
Over 6000 products
Loading...
PRODUCT CODE
HONEYWELL-SPM-FLEX-UNIT

The SPM Flex Chemcassette Tape-Based Gas Detector can be used to extract gas samples from the environment or from a remote point to the chemcassette system.

* Required Fields

    £10,760.40 £8,967.00

    Honeywell SPM Flex Unit

    SPM Flex Chemcassette Tape-Based Gas Detector

    The SPM Flex Chemcassette Tape-Based Gas Detector is a device that extracts gas samples from a local area or from a remote point to a Chemcassette tape-based gas detection system. There are a range of Chemcassette cartridges available for the detection of gases that are either used or formed in semiconductor manufacturing and industrial environments. The device uses an LCD screen and LEDs to display information regarding gas concentration, alarm, fault and status information.

    Applications of the SPM Flex include semiconductor manufacturing plants and industrial environments where workers may be exposed to certain gases. The device is available in two configurations: portable and fixed. The portable configuration includes a handle for easy transportation around site, whilst the fixed configuration can be mounted.  The fixed version will be supplied with a mounting bracket. The SPM Flex is designed to withstand harsh weather conditions ensuring that the device is up and running even in those circumstances without affecting the accuracy of the system. Its Teflon coating ensures that the system does not attract dust. New enhancements of the system include a flip screen and additional gas formulas.

    The data on the SPM Flex system can also be viewed at a distance due to its colour coded LED bar so users can see the data presented even whilst they are away from the device. The web functions of the device allow remote viewing of the data in different rooms, for example. The SPM Flex allows you to plug in an ethernet cable to take advantage of this functionality.

    There are accessories available for the SPM Flex such as a weather shield for use in a fixed manner (with mounting hardware), universal power supply (no cord supplied) and a 10-inch ethernet cable with a weatherproof connector. For more information on the accessories available please get in touch with us.

    Available options include:

    Part Number

    Description

    SPMF-F1GB

    Honeywell SPM Flex Fixed Unit for Great Britain

    SPMF-P1GB

    Honeywell SPM Flex Portable Unit for Great Britain

    Key Features
    • Intuitive and easy to use
    • Fast start up time (under 2 minutes) meaning workers can gear up quickly and get to work
    • Holds up to 3 months history of information and you can view the data on the web or download to USB
    • Easy to maintain – with serviceable parts
    • Long lasting battery life
    • IP65 dust and water resistant
    • Detects gases such as hydrides, amines, oxidizers and mineral acids
    Specifications

    Please see the specification sheet for more information

    Weight

    9.1 lbs (4.1 kg)

    Dimensions

    • Height: 13.2 in. (33.6 cm); Width: 7.2 in. (18.3 cm);
    • Depth without handle: 6.4 in. (16.3 cm); Depth with handle: 9.5 in. (24.1 cm)

    Data logging

    • Rolling up to 3 months (15-22 sec. with no gas reading, 1-2 sec. when reading gas)
    • Event history (1500 events – approx. 1 year)

    Power consumption

    ~1.9 A at 24 VDC +/- 10% (including battery-charging current).

    Chemcassette tape

    14, 30 or 90 day cartridges for 7 specific family gases

    Power supply

    Universal Line powered (90-260 VAC 50/60 Hz) for battery charger.

    Battery type

    Lithium ion

    Battery life

    • 6+ hours under typical conditions – acts as battery back-up in fixed applications
    • Approximately 70% of its originalcapacity after 300 full charge/discharge cycles.

    Power adaptor

    • Input: 90~264 VAC, 1.2A, 47-63 Hz.
    • Output: 24 VDC, 3.75 A max.

    Wire gauges

    • Minimum: 24
    • Maximum: 14. AWG for relay and 4-20 mA outputs.

    Detection technique

    • Chemcassette tape-based with advanced self-monitoring optics design and K-factor multiplier options.
    • Duty cycle options to save paper

    Mounting screws

    • Concrete: 5/16 in x 2 in vibration-resistant stud anchor for concrete (McMaster-Carr 94475A185 or equivalent)
    • Add 0.25 in. to length when mounting bracket with sun shiel
    • Wood: 5/16 in. x 2 in. flange head lag screw for wood (McMaster-Carr 95526A375 or equivalent)
    • Add 0.25 in. to length when mounting bracket with sun shield.

    Operating temperature

    32°F to 104°F (0°C to 40°C) for most gases/applications.

    Operating humidity

    • 0-100% RH for unit (Sample RH limited per tape/calibration)
    • Sample line requires additional hardware to remove moisture in high RH conditions where condensing may occur
    • The sample must be non-condensing
    • Dry conditions may require humidification

    Local alarms/status

    • Visual: LEDs for alarm, normal condition, fault and external power.
    • Audible: User selectable: Off, Low ~75 dB at 1 m, Medium ~85 dB at 1 m, High >90 dB at 1
    • Interface
    • 4 large buttons
    • 3.5 in. Color LCD TFT display
    • Web server
    • Flip screen.

    USB

    2.0 or later.

    Indoor/outdoor use

    Both (the power supply provided is indoor only)

    Operating altitudes

    -1,000 to 3,000 ft. above sea level: standard; 3,000 ft. to 6,000 ft. above sea level: requires adjustment by Honeywell Analytics

    Relays

    250V AC, 6 A maximum.

    Communication options

    • Relays: Alarm 1, Alarm 2, Fault (user configurable for normally open/closed)
    • 4-20mA
    • Ethernet (with Modbus TCP/IP and web server).
    • USB port (for memory stick configuration/data transfer).
    • Communications connector and optional communications cable: 60 V, 5 A maximum.

    Certifications ; detector

    • UL 61010-1, 3rd Edition, 2012-05 (ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL, AND
    • LABORATORY USE - Part 1: General Requirements).
    • CAN/CSA-C22.2 No. 61010-1, 3rd Edition, 2012-05, (ELECTRICAL EQUIPMENT FOR MEASUREMENT,
    • CONTROL, AND LABORATORY USE - Part 1: General Requirements).
    • IEC 61010-1:2010, 3rd Edition.

    RFID Approvals

    • USA (FCC), Canada (IC), Mexico (IFT), Japan (IFERW), Singapore, Taiwan, Korea, China (CMIIT), Malaysia,
    • Australia (RCM), New Zealand (R-NZ), Europe (RED).

    Battery

    • UL/cUL Recognition to UL 2054 + 60950-1.
    • IEC 62133 1st Edition CB Certification.
    • UN Test Report to UN 38.3.

    ce marking

    EMC, LVD, ROHS, WEEE & RED.

    Chemcassette tape

    14, 30 or 90 day cartridges for 7 specific family gases

    Duty cycle options

    Duty cycle options to conserve chemcassette tape in high background applications.

    RFID Labels

    • Smart radio frequency FD labels affixed to cartridges for error-proof use and quick gas selection.
    • Chem keys no longer required.

    Filters

    Most gases require a filter. See manual for filter requirements.

    • Accessories

      SPMF-WAND - Sample Wand Kit (includes probe, filter/holder, coiled tube, mounting hardware)

      SPMF-STRP - Clean Room Suitable Shoulder Strap

      SPMF-HNDL - Handle for Portable configuration

      SPMF-WTHR - Weather Shield for use in Fixed configuration (includes mounting hardware)

      SPMF-PWRS - Universal Power Supply (no cord)

      SPMF-PCON - 6' Power Cable with Weather proof connector (for connection to user 24VDC)

      SPMF-ECON - 10' Ethernet Cable with Weather proof connector male, standard male

      SPMF-CCON - Communication SPM Flex side connector and 6' communication cable with Weather proof connector and pig tale

      1265-2014 - SPM Flex Optics Test Card

      SPMF-MBST - Standard Mounting Bracket for Fixed Unit (for SPM Flex only)

      SPMF-MBRF - Retro-Fit Mounting Bracket for Fixed Unit (compatible with original SPM)

      1998M0871 - SPM Flex CD (manual/software) and Quick Start Guide (printed)

    • Consumables

      1265-4000 - SPM Flex CC-S XP Hydrides

      1265-4001 - SPM Flex CC-S XP Mineral Acids

      1265-4002 - SPM Flex CC-S XP Chlorine

      1265-4003 - SPM Flex CC-S XP Ammonia

      1265-4004 - SPM Flex CC-S Fluorine Oxidizers

      1265-4005 - SPM Flex CC-S Sulfur Dioxide

      1265-4006 - SPM Flex CC-S Diisocyanates

      1265-4007 - SPM Flex CC-S XP Phosgene

      1265-4008 - SPM Flex CC-S Hydrazine

      1265-4009 - SPM Flex CC-S Hydrogen Cyanide

      1265-4010 - SPM Flex CC-S Hydrogen Peroxide

      1265-4011 - SPM Flex CC-S Ozone

      1265-401 - SPM Flex CC-S-U XP Mineral Acids

      1265-3000SPM Flex CC XP Hydrides (90)

      1265-3001 SPM Flex CC XP Mineral Acids (90)

      1265-3002 - SPM Flex CC XP Chlorine (90)

      1265-3003 - SPM Flex CC XP Ammonia (90)

      1265-3004 - SPM Flex CC Fluorine Oxidizers (30)

      1265-3005 - SPM Flex CC Sulfur Dioxide (30)

      1265-3006 - SPM Flex CC Diisocyanates (30)

      1265-3007 - SPM Flex CC XP Phosgene (90)

      1265-3008 - SPM Flex CC Hydrazine (30)

      1265-3010 - SPM Flex CC Hydrogen Peroxide (30)

      1265-3011 - SPM Flex CC Ozone (30)

      1265-3012 - SPM Flex CC-U XP Mineral Acids (90)

    • Spares

      1265A0070 - Main PCB

      1265A0074 - User interface / display PCB

      1265-0153 - User interface ribbon cable

      1265A0080 - RFID PCB

      1265A0321 - RFID/Hall Effect cable assembly

      1265A0511 - Hall effect PCB

      0140-0013 - Coin battery CR2302 Energizer

      1265A0413 - Pump

      1265A0404 - Optics and Gate motor assembly

      1265A0422 - Tape advance stepper motor

      1265-0035 - Clear door

      1265A0182 - Replacement latch assembly for clear door

      1265-0082 - Power switch / USB cover

      1265-0165 - Warning label for power switch / USB cover

      1265-0036 - Clear door gasket

      SPMF-DCET - Dust cover For Ethernet port SPMF-DCET

      SPMF-DCCO - Dust cover For communication port SPMF-DCCO

      SPMF-DCPO - Dust cover For power port

      1265-0174 - Packaging kit for SPM Flex

      0235-0095 - Union Fitting- use to connect disposable end of line filter to tubing

      102599 -Tubing 1/4" O.D  x 1/8" I.D  FEP-for sample inlet, price per foot

      100440 -Tubing Polypropylene 1/4" O.D x 3/16" ID for exhaust , price per foot.

      1991-0147 - Corrosive end of line filter

      780248 -Standard end of line filter

      871134 -Small acid scrubber/filter

      710235 -Standard size scrubber/filter

      874558 -Great Britain Power Cord

      874561 -Europe Power Cord

    Take advantage of our web-exclusive free UK mainland* delivery offer on orders over £100 ex VAT.  See all costs for delivery below and visit our main delivery page for more information on timescales as some restrictions may apply.

    UK & Ireland Delivery Options

    UK Mainland Standard Delivery on orders under £100 ex VAT - £7.95 ex VAT*
    UK Mainland Express Delivery - £21.50 ex VAT (timescales vary – please see delivery page)
    Highlands Delivery - £25.00 ex VAT
    Channel Island Delivery - £40 ex VAT
    Northern Ireland & Republic of Ireland - £25 ex VAT
    Saturday Delivery Options – Please contact us on 0141 771 7749 for more info

    Standard delivery timescales are normally 3-5 working days, depending on stock availability.  Express delivery is normally 1-3 working days, depending on stock availability.  Although we carry an extensive stock, there may be some items that are unavailable due to quantities or otherwise.  In this case we will inform you of the status of your order and whether or not it can be fulfilled within our standard delivery timeframe. *Mainland UK delivery excludes Northern Ireland, other charges apply.

    Please visit our main delivery page for more terms and conditions or contact our Sales Team on 0141 771 7749  or [email protected] for more information. Currently, some manufacturers are facing production and delivery issues due to Brexit and custom clearance and this is affecting lead times of even some of our standard stocked items.  We're trying our best to prevent these issues from affecting orders but please be aware that there may be some delays.  We are aiming to communicate this as best and as early as possible. 

    International Delivery Options

    Delivery costs vary between countries.  Please visit our main delivery page for more information.

    You also have the option to 'Arrange Your Own Courier', whereby you organise the shipment of your own goods once they have reached our warehouse.

    ORDER CANCELLATION AND GOODS RETURN

    Should you wish to cancel an order or return unwanted goods please follow the procedures detailed below to help us ensure cancellations/returns are processed as quickly and efficiently as possible.

    Simply log on to your customer account, note the order reference number and email the full cancellation details to [email protected] or contact us on 0141 771 7749. Assuming the order has not been despatched we will cancel.

    You have the right to cancel the purchase of goods without having to give a reason at any time within the “cooling off period” of fourteen working days, beginning the day after you take delivery of your order.

    You must notify us of your cancellation in writing via email to [email protected] or to our contact address. (Details Here)

    If you are in possession of the goods you are under the duty to retain them and take reasonable care of them.

    You must send the goods back to us in their original condition to our contact address at your own cost (unless we delivered the item to you in error or the item is damaged or defective) as soon as possible once you have cancelled the contract.

    Alternatively we will collect the goods from you which will incur a charge no greater than the actual cost of arranging the collection and shipping. In this case you must make the goods available for collection. We will contact you to make further arrangements.

    We reserve the right to make a charge not exceeding our direct costs of recovering the goods if you do not return the goods or return them at our expense.

    Upon receipt of returned items in satisfactory condition we will arrange a full credit by the same method used to pay for the goods originally. Any credit due will be processed within a maximum of thirty days.

    Note: If you wish to return goods for refund or exchange after 14 days, a re-stocking fee of 20% of the full order total will apply.

    If upon receipt of goods you find them to be faulty, damaged or if you have been incorrectly supplied an item, you should notify us within 24 hours by contacting 0141 771 7749 or [email protected] and quoting your order number and contact details.

    Frontline Safety will arrange uplift of any damaged or wrongly received goods and if on inspection of goods we also find them to be damaged, faulty or incorrectly supplied, we will offer replacement goods or provide a full refund.

    We recommend you inspect all goods prior to signing for and accepting delivery. If there is any visible damage to the outer packaging, ensure goods are sign for as damaged. In instances where it isn’t possible to sign for goods as damaged, these should be signed for as unexamined.


    Note: If your goods happen to develop a fault out with the standard returns period but within supplied warranty period or if you require any additional assistance, please contact us on 0141 771 7749 or email [email protected]

    IMPORTANT INFORMATION

    All postage, handling, customs and duty charges for all returned goods are the responsibility of the customer. We recommend using a fully traceable, insured service as goods are your responsibility while in transit.

    SPM Flex Chemcassette Tape-Based Gas Detector

    The SPM Flex Chemcassette Tape-Based Gas Detector is a device that extracts gas samples from a local area or from a remote point to a Chemcassette tape-based gas detection system. There are a range of Chemcassette cartridges available for the detection of gases that are either used or formed in semiconductor manufacturing and industrial environments. The device uses an LCD screen and LEDs to display information regarding gas concentration, alarm, fault and status information.

    Applications of the SPM Flex include semiconductor manufacturing plants and industrial environments where workers may be exposed to certain gases. The device is available in two configurations: portable and fixed. The portable configuration includes a handle for easy transportation around site, whilst the fixed configuration can be mounted.  The fixed version will be supplied with a mounting bracket. The SPM Flex is designed to withstand harsh weather conditions ensuring that the device is up and running even in those circumstances without affecting the accuracy of the system. Its Teflon coating ensures that the system does not attract dust. New enhancements of the system include a flip screen and additional gas formulas.

    The data on the SPM Flex system can also be viewed at a distance due to its colour coded LED bar so users can see the data presented even whilst they are away from the device. The web functions of the device allow remote viewing of the data in different rooms, for example. The SPM Flex allows you to plug in an ethernet cable to take advantage of this functionality.

    There are accessories available for the SPM Flex such as a weather shield for use in a fixed manner (with mounting hardware), universal power supply (no cord supplied) and a 10-inch ethernet cable with a weatherproof connector. For more information on the accessories available please get in touch with us.

    Available options include:

    Part Number

    Description

    SPMF-F1GB

    Honeywell SPM Flex Fixed Unit for Great Britain

    SPMF-P1GB

    Honeywell SPM Flex Portable Unit for Great Britain

    Key Features
    • Intuitive and easy to use
    • Fast start up time (under 2 minutes) meaning workers can gear up quickly and get to work
    • Holds up to 3 months history of information and you can view the data on the web or download to USB
    • Easy to maintain – with serviceable parts
    • Long lasting battery life
    • IP65 dust and water resistant
    • Detects gases such as hydrides, amines, oxidizers and mineral acids
    Specifications

    Please see the specification sheet for more information

    Weight

    9.1 lbs (4.1 kg)

    Dimensions

    • Height: 13.2 in. (33.6 cm); Width: 7.2 in. (18.3 cm);
    • Depth without handle: 6.4 in. (16.3 cm); Depth with handle: 9.5 in. (24.1 cm)

    Data logging

    • Rolling up to 3 months (15-22 sec. with no gas reading, 1-2 sec. when reading gas)
    • Event history (1500 events – approx. 1 year)

    Power consumption

    ~1.9 A at 24 VDC +/- 10% (including battery-charging current).

    Chemcassette tape

    14, 30 or 90 day cartridges for 7 specific family gases

    Power supply

    Universal Line powered (90-260 VAC 50/60 Hz) for battery charger.

    Battery type

    Lithium ion

    Battery life

    • 6+ hours under typical conditions – acts as battery back-up in fixed applications
    • Approximately 70% of its originalcapacity after 300 full charge/discharge cycles.

    Power adaptor

    • Input: 90~264 VAC, 1.2A, 47-63 Hz.
    • Output: 24 VDC, 3.75 A max.

    Wire gauges

    • Minimum: 24
    • Maximum: 14. AWG for relay and 4-20 mA outputs.

    Detection technique

    • Chemcassette tape-based with advanced self-monitoring optics design and K-factor multiplier options.
    • Duty cycle options to save paper

    Mounting screws

    • Concrete: 5/16 in x 2 in vibration-resistant stud anchor for concrete (McMaster-Carr 94475A185 or equivalent)
    • Add 0.25 in. to length when mounting bracket with sun shiel
    • Wood: 5/16 in. x 2 in. flange head lag screw for wood (McMaster-Carr 95526A375 or equivalent)
    • Add 0.25 in. to length when mounting bracket with sun shield.

    Operating temperature

    32°F to 104°F (0°C to 40°C) for most gases/applications.

    Operating humidity

    • 0-100% RH for unit (Sample RH limited per tape/calibration)
    • Sample line requires additional hardware to remove moisture in high RH conditions where condensing may occur
    • The sample must be non-condensing
    • Dry conditions may require humidification

    Local alarms/status

    • Visual: LEDs for alarm, normal condition, fault and external power.
    • Audible: User selectable: Off, Low ~75 dB at 1 m, Medium ~85 dB at 1 m, High >90 dB at 1
    • Interface
    • 4 large buttons
    • 3.5 in. Color LCD TFT display
    • Web server
    • Flip screen.

    USB

    2.0 or later.

    Indoor/outdoor use

    Both (the power supply provided is indoor only)

    Operating altitudes

    -1,000 to 3,000 ft. above sea level: standard; 3,000 ft. to 6,000 ft. above sea level: requires adjustment by Honeywell Analytics

    Relays

    250V AC, 6 A maximum.

    Communication options

    • Relays: Alarm 1, Alarm 2, Fault (user configurable for normally open/closed)
    • 4-20mA
    • Ethernet (with Modbus TCP/IP and web server).
    • USB port (for memory stick configuration/data transfer).
    • Communications connector and optional communications cable: 60 V, 5 A maximum.

    Certifications ; detector

    • UL 61010-1, 3rd Edition, 2012-05 (ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL, AND
    • LABORATORY USE - Part 1: General Requirements).
    • CAN/CSA-C22.2 No. 61010-1, 3rd Edition, 2012-05, (ELECTRICAL EQUIPMENT FOR MEASUREMENT,
    • CONTROL, AND LABORATORY USE - Part 1: General Requirements).
    • IEC 61010-1:2010, 3rd Edition.

    RFID Approvals

    • USA (FCC), Canada (IC), Mexico (IFT), Japan (IFERW), Singapore, Taiwan, Korea, China (CMIIT), Malaysia,
    • Australia (RCM), New Zealand (R-NZ), Europe (RED).

    Battery

    • UL/cUL Recognition to UL 2054 + 60950-1.
    • IEC 62133 1st Edition CB Certification.
    • UN Test Report to UN 38.3.

    ce marking

    EMC, LVD, ROHS, WEEE & RED.

    Chemcassette tape

    14, 30 or 90 day cartridges for 7 specific family gases

    Duty cycle options

    Duty cycle options to conserve chemcassette tape in high background applications.

    RFID Labels

    • Smart radio frequency FD labels affixed to cartridges for error-proof use and quick gas selection.
    • Chem keys no longer required.

    Filters

    Most gases require a filter. See manual for filter requirements.

    • Accessories

      SPMF-WAND - Sample Wand Kit (includes probe, filter/holder, coiled tube, mounting hardware)

      SPMF-STRP - Clean Room Suitable Shoulder Strap

      SPMF-HNDL - Handle for Portable configuration

      SPMF-WTHR - Weather Shield for use in Fixed configuration (includes mounting hardware)

      SPMF-PWRS - Universal Power Supply (no cord)

      SPMF-PCON - 6' Power Cable with Weather proof connector (for connection to user 24VDC)

      SPMF-ECON - 10' Ethernet Cable with Weather proof connector male, standard male

      SPMF-CCON - Communication SPM Flex side connector and 6' communication cable with Weather proof connector and pig tale

      1265-2014 - SPM Flex Optics Test Card

      SPMF-MBST - Standard Mounting Bracket for Fixed Unit (for SPM Flex only)

      SPMF-MBRF - Retro-Fit Mounting Bracket for Fixed Unit (compatible with original SPM)

      1998M0871 - SPM Flex CD (manual/software) and Quick Start Guide (printed)

    • Consumables

      1265-4000 - SPM Flex CC-S XP Hydrides

      1265-4001 - SPM Flex CC-S XP Mineral Acids

      1265-4002 - SPM Flex CC-S XP Chlorine

      1265-4003 - SPM Flex CC-S XP Ammonia

      1265-4004 - SPM Flex CC-S Fluorine Oxidizers

      1265-4005 - SPM Flex CC-S Sulfur Dioxide

      1265-4006 - SPM Flex CC-S Diisocyanates

      1265-4007 - SPM Flex CC-S XP Phosgene

      1265-4008 - SPM Flex CC-S Hydrazine

      1265-4009 - SPM Flex CC-S Hydrogen Cyanide

      1265-4010 - SPM Flex CC-S Hydrogen Peroxide

      1265-4011 - SPM Flex CC-S Ozone

      1265-401 - SPM Flex CC-S-U XP Mineral Acids

      1265-3000SPM Flex CC XP Hydrides (90)

      1265-3001 SPM Flex CC XP Mineral Acids (90)

      1265-3002 - SPM Flex CC XP Chlorine (90)

      1265-3003 - SPM Flex CC XP Ammonia (90)

      1265-3004 - SPM Flex CC Fluorine Oxidizers (30)

      1265-3005 - SPM Flex CC Sulfur Dioxide (30)

      1265-3006 - SPM Flex CC Diisocyanates (30)

      1265-3007 - SPM Flex CC XP Phosgene (90)

      1265-3008 - SPM Flex CC Hydrazine (30)

      1265-3010 - SPM Flex CC Hydrogen Peroxide (30)

      1265-3011 - SPM Flex CC Ozone (30)

      1265-3012 - SPM Flex CC-U XP Mineral Acids (90)

    • Spares

      1265A0070 - Main PCB

      1265A0074 - User interface / display PCB

      1265-0153 - User interface ribbon cable

      1265A0080 - RFID PCB

      1265A0321 - RFID/Hall Effect cable assembly

      1265A0511 - Hall effect PCB

      0140-0013 - Coin battery CR2302 Energizer

      1265A0413 - Pump

      1265A0404 - Optics and Gate motor assembly

      1265A0422 - Tape advance stepper motor

      1265-0035 - Clear door

      1265A0182 - Replacement latch assembly for clear door

      1265-0082 - Power switch / USB cover

      1265-0165 - Warning label for power switch / USB cover

      1265-0036 - Clear door gasket

      SPMF-DCET - Dust cover For Ethernet port SPMF-DCET

      SPMF-DCCO - Dust cover For communication port SPMF-DCCO

      SPMF-DCPO - Dust cover For power port

      1265-0174 - Packaging kit for SPM Flex

      0235-0095 - Union Fitting- use to connect disposable end of line filter to tubing

      102599 -Tubing 1/4" O.D  x 1/8" I.D  FEP-for sample inlet, price per foot

      100440 -Tubing Polypropylene 1/4" O.D x 3/16" ID for exhaust , price per foot.

      1991-0147 - Corrosive end of line filter

      780248 -Standard end of line filter

      871134 -Small acid scrubber/filter

      710235 -Standard size scrubber/filter

      874558 -Great Britain Power Cord

      874561 -Europe Power Cord

    Take advantage of our web-exclusive free UK mainland* delivery offer on orders over £100 ex VAT.  See all costs for delivery below and visit our main delivery page for more information on timescales as some restrictions may apply.

    UK & Ireland Delivery Options

    UK Mainland Standard Delivery on orders under £100 ex VAT - £7.95 ex VAT*
    UK Mainland Express Delivery - £21.50 ex VAT (timescales vary – please see delivery page)
    Highlands Delivery - £25.00 ex VAT
    Channel Island Delivery - £40 ex VAT
    Northern Ireland & Republic of Ireland - £25 ex VAT
    Saturday Delivery Options – Please contact us on 0141 771 7749 for more info

    Standard delivery timescales are normally 3-5 working days, depending on stock availability.  Express delivery is normally 1-3 working days, depending on stock availability.  Although we carry an extensive stock, there may be some items that are unavailable due to quantities or otherwise.  In this case we will inform you of the status of your order and whether or not it can be fulfilled within our standard delivery timeframe. *Mainland UK delivery excludes Northern Ireland, other charges apply.

    Please visit our main delivery page for more terms and conditions or contact our Sales Team on 0141 771 7749  or [email protected] for more information. Currently, some manufacturers are facing production and delivery issues due to Brexit and custom clearance and this is affecting lead times of even some of our standard stocked items.  We're trying our best to prevent these issues from affecting orders but please be aware that there may be some delays.  We are aiming to communicate this as best and as early as possible. 

    International Delivery Options

    Delivery costs vary between countries.  Please visit our main delivery page for more information.

    You also have the option to 'Arrange Your Own Courier', whereby you organise the shipment of your own goods once they have reached our warehouse.

    ORDER CANCELLATION AND GOODS RETURN

    Should you wish to cancel an order or return unwanted goods please follow the procedures detailed below to help us ensure cancellations/returns are processed as quickly and efficiently as possible.

    Simply log on to your customer account, note the order reference number and email the full cancellation details to [email protected] or contact us on 0141 771 7749. Assuming the order has not been despatched we will cancel.

    You have the right to cancel the purchase of goods without having to give a reason at any time within the “cooling off period” of fourteen working days, beginning the day after you take delivery of your order.

    You must notify us of your cancellation in writing via email to [email protected] or to our contact address. (Details Here)

    If you are in possession of the goods you are under the duty to retain them and take reasonable care of them.

    You must send the goods back to us in their original condition to our contact address at your own cost (unless we delivered the item to you in error or the item is damaged or defective) as soon as possible once you have cancelled the contract.

    Alternatively we will collect the goods from you which will incur a charge no greater than the actual cost of arranging the collection and shipping. In this case you must make the goods available for collection. We will contact you to make further arrangements.

    We reserve the right to make a charge not exceeding our direct costs of recovering the goods if you do not return the goods or return them at our expense.

    Upon receipt of returned items in satisfactory condition we will arrange a full credit by the same method used to pay for the goods originally. Any credit due will be processed within a maximum of thirty days.

    Note: If you wish to return goods for refund or exchange after 14 days, a re-stocking fee of 20% of the full order total will apply.

    If upon receipt of goods you find them to be faulty, damaged or if you have been incorrectly supplied an item, you should notify us within 24 hours by contacting 0141 771 7749 or [email protected] and quoting your order number and contact details.

    Frontline Safety will arrange uplift of any damaged or wrongly received goods and if on inspection of goods we also find them to be damaged, faulty or incorrectly supplied, we will offer replacement goods or provide a full refund.

    We recommend you inspect all goods prior to signing for and accepting delivery. If there is any visible damage to the outer packaging, ensure goods are sign for as damaged. In instances where it isn’t possible to sign for goods as damaged, these should be signed for as unexamined.


    Note: If your goods happen to develop a fault out with the standard returns period but within supplied warranty period or if you require any additional assistance, please contact us on 0141 771 7749 or email [email protected]

    IMPORTANT INFORMATION

    All postage, handling, customs and duty charges for all returned goods are the responsibility of the customer. We recommend using a fully traceable, insured service as goods are your responsibility while in transit.