Industrial Scientific Tango TX2 Dual Gas Monitor (Diffusion)

PRODUCT CODE:
IS-TANGOTX2-D-D

The Tango TX2 is a reliable dual-gas monitor with increased accuracy as it uses two individual sensors to detect gas. The device is a serviceable monitor that does not need to be charged, comes with a two-year runtime battery and a Guaranteed for Life Industrial Scientific Warranty. This monitor is also compatible with iNet Exchange and the DSXI docking station to assist with maintenance and reporting.

Loading...
£606.00
Final product price inc VAT

Product description

Industrial Scientific Tango TX2 Dual Gas Monitor (Diffusion)

The Tango TX2 can detect up to two gases, using two individual sensors to increase alarm accuracy, making it Industrial Scientifics “most reliable two-gas monitor on the market”. The replaceable battery within the monitor has a two-year run time that does not need to be charged, removing the hassle of device charging and simplifying the gas detector management process.

Each TX2 can be assigned personally to each user to help increase workers ownership and save time managing the fleet of detectors at each application. Overall, this monitor can reduce false alarms, protect workers and streamline operations. 

The TX2 is also compatible with the DSXi Docking Station that can perform calibrations, automatic bump testing, automated software and firmware updates and can upload data each time a monitor is docked.

Key Features

  • LCD screen
  • Protective rubber over mould case made of polycarbonate and conductive polycarbonate.
  • Tripple alarm system featuring three flashing coloured LED’s, 100 dB noise alarm and a vibrating alarm.
  • IP66/7 rating means the monitor is fully dust-tight, protected against direct high-pressure jets and water immersion for up to 30mins at depths of 15cm-1m.
Specification

INSTRUMENT WARRANTY

Guaranteed for Life™. Warranted for as long as the instrument is supported by Industrial Scientific Corporation (excludes sensors, batteries, and filters). CO and H2S sensors are warranted for three years. All other sensors are warranted for two years.

DIMENSIONS

99 x 51 x 35 mm (3.9 x 2.0 x 1.4 in)

WEIGHT

126.0 g (4.4 oz)

SENSORS

CO, CO/H2, H2S, NO2, SO2 – Electrochemical sensor technology

SENSOR MEASURING RANGES

Carbon Monoxide (CO): 0 to 1,000 ppm in 1 ppm increments Carbon Monoxide (CO/H2 low): 0 to 1,000 ppm in 1 ppm increments Hydrogen Sulfide (H2S): 0.0 to 500.0 ppm in 0.1 ppm increments Nitrogen Dioxide (NO2): 0.0 to 150.0 ppm in 0.1 ppm increments Sulfur Dioxide (SO2): 0.0 to 150.0 ppm in 0.1 ppm increments

TEMPERATURE RANGE

-40 °C to 50 °C (-40 °F to 122 °F) **

HUMIDITY RANGE

15% to 95% Non-condensing (continuous)

BATTERY

3.6 V Primary lithium-thionyl chloride (Li-SOCl2); 1.5AH, 2/3AA; replaceable; non rechargeable; always on; up to 2-year run time depending on operating conditions

DATA LOGGING

3 months at 10-second intervals

EVENT LOGGING

60 alarm events

CERTIFICATIONS

DIRECTIVE OR CB AREA CLASSIFICATION STANDARDS

 

ATEX1: Ex ia I Ma;

Ex ia IIC T4 Ga; Equipment Group and Category: I M1 and II 1G,

EN 60079-0: 2012

EN 60079-11: 2012

EN 50303: 2000

 

IECEx3 Ex ia I Ma, Ex ia IIC T4 Ga

IEC 60079-0: 2011

IEC 60079-11: 2011

 

UL (C-US)4: Class I, Groups A, B, C, and D; Class II, Groups E, F, and G; T4; Exia Class I, Zone 0, AEx ia IIC T4

 

UL 913 8th Ed.

UL 60079-0 6th Ed.

UL 60079-11 6th Ed.

CSA C22.2 No. 157

 

* These specifications are based on performance averages and may vary by instrument.

 

** Operating temperatures above 50 °C (122 °F) may cause reduced instrument accuracy. Operating temperatures below -20 °C (-4 °F) may cause reduced instrument accuracy and affect display and alarm performance.

 

Patent No. 9,000,910 – DualSense® Technology | Patent No. 9,064,386 – AlarmAmp™