MiniRAE 3000+ (PGM-7320) Photoionisation (PID) Detector with 10.6eV lamp / Non- Wireless
The MiniRAE 3000+ is a photoionisation (PID) detector from RAE Systems. It's capable of detecting more than 200 volatile organic compounds (VOCs) with an extended measuring range of 0-15,000 ppm and 10.6 eV lamp.
This PID gas detector is ideal for tough industries including leak detection and use of hazardous materials. The proven PID technology includes a patented sensor which has an extremely fast response time and accounts for humidity compensation. You can view real-time sensor readings.
RAE System's MiniRAE 3000+ is easily maintainable with interchangeable battery packs, automatic lamp recognition and easy access to the sensor. It uses advanced technology and has some advantageous features. It has a tough but flexible inlet Flexi-probe, a built-in sample pump and a double alarm system. Alarms include a 95dB audible alarm and bright red flashing alarm.
- Simple to use and easy to access, even with gloves on
- Large graphical display with user-friendly screens
- Integrated flashlight increases visibiltiy in dark conditions
- Supports 12 different languages
- IP67 housing makes it waterproof and easy to clean
- Includes a protective, but removable, rubber boot
What's Included |
• MiniRAE 3000 Monitor, Model PGM-7320 |
Gas 1 | VOCs |
Range (ppm) | 0 to 999.9 |
Resolution (ppm) | 0.1 |
Response Time (T90) | < 3 sec |
Gas 2 | VOCs |
Range (ppm) | 1000 to 15,000 |
Resolution (ppm) | 1 |
Response Time (T90) | < 3 sec |
Size | 10" L x 3.0" W x 2.5" H (25.5 cm x 7.6 cm x 6.4 cm) |
Weight | 26 oz (738 g) |
Sensors | Photoionization sensor with standard 10.6 eV lamp |
Battery |
|
Operating Time | 16 hours of operation (12 hours with alkaline battery) |
Display Graphic | 4 lines, 28 x 43 mm, with LED backlight for enhanced display readability |
Keypad | 1 operation and 2 programming keys, 1 flashlight on/off |
Direct Readout |
|
Alarms |
|
EMI/RFI |
|
IP Rating |
|
Data Logging | Standard 6 months at one-minute intervals |
Calibration | 2-point or 3-point calibration for zero and span. Calibration memory for 8 calibration gases, alarm limits, span values and calibration dates |
Sampling Pump |
|
Low Flow Alarm | Auto shut-off pump at low-flow condition |
Communication | Download data and upload instrument setup from PC through charging cradle |
Certifications |
|
Operating Temperature | -4° to 122° F (-20° to 50° C) |
Humidity | 0 to 95% relative humidity (non-condensing) |
Attachments | Durable bright yellow rubber boot |
Warranty | 3 years for 10.6 eV lamp, 1 year for pump, battery, sensor and instrument |