MSA Ultima X5000 - Gas Monitor / Dual Sensor with Relay
The MSA Ultima X5000 is the future of Gas Detection for oxygen, toxic, and combustible gases. With an advanced Organic LED (OLED) Display that is visible from a distance up to 50ft and its unique touch screen interface means no tools are required to operate. Calibration cycles can be extended by up to 18 months due to MSA’s XCell sensors and their patented TruCal technology.
The Ultima X5000 provides worriless operation, self-checking 4 times a day for more stability and increased calibration cycles through TruCal. It also compensates for factors that result in electrochemical sensor drift by monitoring sensor integrity and compensating for factors that may impact this (H2S & CO digital sensors only).
Every 6 hours an acoustic signal is sent ensuring the sensor inlets are not blocked, known as diffusion supervision. This also recognises when sensors are blocked and puts the unit into fault mode if blocked. Once the blockage is cleared the device will return to normal operation.
Gas sensors can be replaced quickly and safely without turning off the device due to patented SafeSwap technology, fully displaying the benefits of this device. The Ultima X5000 is fully configurable allowing it to be designed to your specific needs and can suited for use in a variety of applications.
- Industry-first touch screen interface
- IP66
- Fits current X Series wall mounts
- Alerts up to 75ft away via Bluetooth
- Bright green, yellow and red status LEDs
- X/S connect app (reduce setup time by 50%)
- Alarms and settings are adjustable
Combustible Gas Sensor Type |
Catalytic Bead (XCell Comb) Infrared (XIR PLUS) |
||
Toxic Gas & Oxygen Sensor Type |
Carbon Dioxide CO2 (XIR Plus) Carbon Monoxide CO (XCell Toxic) Carbon Monoxide CO H2-Resistant (XCell Toxic) Hydrogen Sulphide H2S (XCell Toxic) Oxygen O2 (XCell O2) Sulphur Dioxide SO2 (XCell SO2) |
||
Sensor Measuring Ranges |
Combustible: 0-100% LEL CO2: 0-2%, 0-5% Vol CO: 0-100, 0-500, 0-1000 ppm CO-H2Resist: 0-100 ppm H2S: 0-10, 0-50, 0-100 ppm O2: 0-25% SO2: 0-25 ppm |
||
Typical Sensor Life |
5 years – XCell Sensors 10 years - infrared |
||
Sensor Performance |
T90 (Typical) |
Repeatability |
Zero Drift (Per Year) |
XIR Plus Comb |
< 2 sec. |
< +/- 1% LEL |
n/a |
XIR Plus CO2 |
< 6 sec. |
< +/- 1% Vol |
n/a |
XCell Comb |
< 22 sec. |
< +/- 3% LEL |
≤ 5% LEL |
XCell CO |
< 9 sec. |
< +/- 1% |
≤ 1% full scale |
XCell H2S |
< 23 sec. |
< +/- 1% |
≤ 1% full scale |
XCell O2 |
< 11 sec. |
< +/- 0.1% Vol |
≤ 0.2% Vol |
XCell SO2 |
< 6 sec. |
+/- 1% |
≤ 1%FS per mo. |
Approvals Classification |
Divisions (US/Canada) Class I, II, III; Div 1&2, T4/T5/T6; Zones (Global) Ex db nA IIC T5 Gb (Class I, Zone 1/ Zone 2) Ex tb IIIC T85°C Db (Class II, Zone21) Enclosure rating Type 4X, IP66 Markings vary by component. See Manual for specific component markings. |
||
Warranty |
X5000 Transmitter: 2 years XIR PLUS: 10 years source, 5 years electronics XCell Sensors: 3 years |
||
Approvals |
CSA, ATEX, IECEx, Inmetro, DNV Marine, CE Marking. Complies with C22.2 No. 152, FM 6320 RED, FCC, Suitable for SIL 2 |
||
Operating Temperature Range |
XCell: -40°C to +60°C XIR PLUS: -40°C to +60°C (may differ by gas, see manual) |
||
Storage Temperature Range |
40°C to +60°C |
||
Relative Humidity (non-condensing) |
10-95% (XCell Toxics & O2 ) 0-95% (XCell Comb) 15-95% (XIR PLUS) |
||
Input Power |
11 to 30 VDC, 3 wire, <5W nominal |
||
Signal Output |
Dual 4-20 mA current source, HART |
||
Bluetooth (optional) |
Bluetooth Low Energy (BLE) v4.3 or higher |
||
Relay Ratings |
5A @ 30VDC; 5A @220 VAC (3X) SPDT – fault, warn, alarm |
||
Relay Modes |
Common, discrete, horn |
||
Nominal max Power (w/ relays) |
XIR PLUS 6.7W XCell Comb 4.9W XCell Toxic & O2 2.8W XIR PLUS and XCell Comb 10.9W XIR PLUS and XCell Toxic & O2 7.0W Dual XIR PLUS 11.6W Dual XCell Toxic & O2 3.6W Dual XCell Comb 10.6W Dual XCell Comb and XCell Toxic & O2 5.3W |
||
EMC Directive |
Complies with EN 50270, EN 61000-6-4, EN 61000-6-3 |
||
Display |
Organic LED (multi-lingual) with Contrast Ratio of 2000:1 and View Angle of 160° |
||
Hart |
HART 7, HART device description language available |
||
Faults Monitored |
Low supply voltage, RAM checksum error, flash checksum error, EEPROM error, internal circuit error, relay, invalid sensor configuration, sensor faults, calibration faults, general system) |
||
Wiring Requirements |
3-wire (single sensor) or 4-wire (dual sensor) shielded cable. Refer to manual for mounting distances and wire gauge. |
||
HOUSING (W X H) w/ XCell Sensor w/ XCell Sensor & XIR Sensor |
5.88” x 5.71” [150 mm x 145mm] 5.88” x 10.15” [150 mm x 258 mm] 13.42” x 10.15” [341 mm x 258 mm] |
||
Lid (Depth) w/ Relay Board w/o Relay board |
4.86” [123mm] 3.86” [98 mm] |
||
Weight |
8.8 lbs (4 kg) - 316 SS |