UltraRAE 3000+ (PGM-7360) Photoionisation (PID) Detector with 9.8 eV lamp Non-Wireless
The UltraRAE 3000+ from RAE Systems is a photoionisation (PID) detector, suitable for the detection of hazardous and volatile organic compounds (VOCs). The PID is capable of detecting more than 200 VOCs, but also features a benzene-specific mode and is Non-Wireless.
This makes the UltraRAE 3000 ideal for pre-sceening applications in refinery and plant maintenance, hazardous material response, marine spill reponse and refinery down-stream monitoring. The detector has an extended range of 0.05 to 10,000ppm in VOC mode and 50 ppb to 200ppm in its benzene-specific mode.
The UltraRAE 3000 comes with a 9.8 eV lamp as standard, but other lamps are available. The sensor response extremely quickly and can produce highly specific readings when using RAE-SEP benzene tubes.
- Easy to read, graphical display
- Multi-language support
- Maintainable with easy access to sensors, lamp and battery without tools
- Specification method reduces risk of false alarms
- Alarm system - flashing light, 95dB buzzer
- IP 65 rated (unit running)
- Datalogging - 6 months at one-minute interval
What’s Included? |
• UltraRAE 3000+ Monitor, Model PGM-7360 with soft leather carrying case
|
Sensor |
Photoionization sensor with standard 9.8 eV or 11.7 eV lamp |
Range |
VOCs – 0 to 99.99 ppm Benzene – 0 to 200 ppm |
Resolution |
VOCs – 0.05 ppm Benzene – 0.05 ppm |
Response Time (T90) |
< 3 s (for VOCs) < 60 s (for Benzene and Butadiene) |
Dimensions |
10” x 3.0” x 2.5” |
Weight |
26 oz (738g) |
Temperature |
-4° to 122°F (-20° to 50°C) |
Humidity |
0-95% RH (non-condensing) |
Battery |
- Alkaline battery adapter - Rechargeable external field-replaceable lithium-ion battery pack if specified |
Operating Hours |
16 hours of operation |
Alarms |
|
IP Rating |
IP65 unit running |
Calibration |
Two-point or three-point calibration for zero and span Calibration memory for 8 calibration gases, alarm limits, span values and calibration dates |
Sampling Pump |
Internal, integrated flow rate at 400 cc/mn |
Low Flow Alarm |
Auto shut-off pump at low-flow condition |
Communication |
Download data and upload instrument set-up from PC through charging cradle |
Hazardous Area Approval |
US and Canada: UL, cUL, Classified as Intrinsically Safe for use in Class I, Division 1 Groups A, B, C, D Europe: ATEX Ex II 2G EEx ia IIC T4 |
Warranty |
3 years for 10.6 ev lamp, 1 year for 9.8 eV lamp, pump, battery, sensor and instrument |
|