The ToxiRAE II Sulfur Dioxide (SO2) Monitor which costs a little more than disposable detectors, continuously displays toxic gas concentrations to the user. Typical disposables only display remaining life whereas RAE’s SO2 detector is fully-featured and provides a continuous, digital display of the gas concentration, STEL, TWA and peak values as well as high and low alarms.
RAE System’s sulfur dioxide detector is a simple-to-use one-button product and is easy to calibrate.
By using or modifying the alarms, specific requirements can be met. These include a bright red flashing alarm, a loud 90 dB buzzer and a built-in vibration alarm.
To assist SO2 detection, the instrument can be hands-free and can clip onto a hardhat, shirt pocket, shoulder strap, or belt. The ABS housing of the ToxiRAE II detector is durable, highly-impact resistant and carbon-loaded.
Once disposable monitors are turned on they stay on until their batteries expire, whereas the ToxiRAE II sulfide dioxide detector allows the user to decide when and where the device is used and can be turned off accordingly.
RAE System’s SO2 detector does not have a pre-programmed expiration date so the user will get the full life out of the battery and sensor. Both of these can be easily replaced in the workplace. Due to the cost of the ToxiRAE II being similar to many reduced-feature disposables, there is a choice to renew the monitor or obtain a fresh, new monitor.
This monitor also comes with a 2 year guarantee, stainless steel alligator clip, wrist strap, calibration gas test adapter and a high-capacity Lithium battery.
It can be applied in fields such as oil production, chemical plants, fire service and power plants.
| Range (ppm) | 0 to 20 |
|
Resolution (ppm) |
0.1 |
| Size |
3.6" x 1.9" x 0.9" (9.3 cm x 4.9 cm x 2.2 cm) |
| Weight | 3.6 oz (102 g) with clip |
| Battery | User-replaceable 2/3 AA high-capacity Lithium battery |
|
Operating Time |
2 years typical battery life for CO/H2S/O2 sensors or 730 minutes of alarm. All other low- or high-bias sensor-equipped models, typical 1 year or 360 minutes of alarm. |
|
Ambient Conditions |
Temperature -40° to 131° F (-40° to 55° C) |
| Pressure | |
|
Humidity 0 to 95% relative humidity (non-condensing) |
|
| Display |
Easy-to-read LCD for continuous display of concentration in ppm and text messages |
| Alarms |
|
|
Data Logging |
Storage of concentration and events with date and time (120 hours @ 1 data set per minute) |
|
IP Rating |
IP-65: protected against dust, protected against low-pressure jets of water from all directions |
| Certification |
|
| Warranty |
2-year warranty for instruments with CO/H2S/O2 sensors (all other sensors have 1-year warranty) |
| Calibration |
Two-point field calibration; auto-zero at startup, user-initiated span/standard reference gas |