Drager Short Term Detection Tubes - Freons 100/a (Pack of 8)

PRODUCT CODE:
8101601

These tubes are designed for spot-measurements and must be used with the Drager Accuro Gas Detection Pump. Buy now from Frontline Safety.

£309.76 inc VAT
£258.13
Loading...

Product description

Drager Detection Tubes - Freons 100/a (Pack of 8)

These short-term detection tubes from Drager are for Freons (100/a).  They come in pack of 10 and have a shelf life of 2 years.

Other substances which can be detected with these tubes include: Bromochlorodifluoromethane (R121b), Chlorobromomethane, Chlorodifluoromethane, Dibromofluoromethane (R122b), Dichlorodifluoromethane (R12), 1,1-Dichloro-1-fluoroethane (R141b), Dichlorofluoronenthane (R21), 3,3-Dichloro-1,1,2,2-pentachloro=propane, 1,3-Dichloro-1,1,2,2-pentachloro=propane, 1,2-Dichloro-1,1,2,2-tetrafluoroethane, 2,2-Dichloro-1,1,1-trifluoroethane (R123), 1,1-Dichloro-2,2,2-trifluoroethane, Fluorodichloromethane, 1,1,2,2-Tetrachloro- 1,2-difluoroethane (R112), 1,1,1,2- Tetrachloro- 2,2-difluoroethane (R112a), Tetrafluoroethane (R134a), Tetrafluoromethane, Trichlorofluoromethane (R11), 1,1,2-Trichloro- 1,2,2-trifluoroethane (R113) and Trifluorobromomethane (R131b).

The Drager Gas Detection Pump (Accuro) is compatible with the short-term gas detection tubes.  You can purchase this product by clicking here .

Key Features

  • Designed for short-term, on-the-spot measurement
  • Can take between 10 seconds to 15 minutes to gather a reading
  • Applications may include concentration fluctuations in the workplace, measurement of contaminants in breathing zone, and confined spaces
  • Can be used as pre-entry checks
Specification
Application Range  
Standard Measuring Range: 200 to 2,600 ppm R 113/R 114
100 to 1,400 ppm R 11
200 to 2,800 ppm R 22
(on request) 1,000 to 4,000 ppm R 134a
The indication is in mm and must be compared to the
calibration data sheets.
Number of Strokes n: 3
Time for Measurement: approx. 1 min
Standard Deviation: ± 30 %
Color Change: blue --> yellow to greyish green
   
Ambient Operating Conditions  
Temperature: 0 to 40 °C
Absolute Humidity: 1 to 15 mg H2O / L
   
Reaction Principle  
For Example:
a) R113 [pyrolysis] --> HCI
b) HCI + pH indicator --> yellow reaction product
 
Cross Sensitivity
Other halogenated hydrocarbons, free halogens and hydrogens halides are also indicated, however, with differing sensitivity. Perchloroethylene is indicated with the same sensitivity as R113.
 
Additional Information
The tubes become very warm during the measurement. Therefore, these tubes should not be used in potentially combustible atmospheres. A combustible gas monitor should be used to qualify any questionable area before conducting a measurement with one of these tubes.