Drager Detection Tubes - Toluene 5/b (Pack of 10)
These toluene short-term detection tubes from Drager Safety have a measurement range of 5 to 300 ppm. As well as detecting Toluene they may be able to detect a range of other substances.
This range may include o,m,p-Chlorotoluene, Diethyl Benzene , Mesitylene, Methyl Chloroacetate, Methyl Cyclopentane, n-Propyl Benzene and Trimethylbenzene.
The tubes have a shelf life of 2 years and come in pack of 10 tubes.
The Drager Gas Detection Pump (Accuro) is compatible with the short-term gas detection tubes. You can purchase this product by clicking here.
- Hard-to-reach and on-the-spot measurements can be carried out using the tubes, pump and accessories
- Obtain measurements within 10 seconds to 15 minutes (depending on the type of tube)
- Pre-entry checks, confined space entry, variations in concentration levels in the workplace and contamination of breathing zones are possible applications which may use tubes
Application Range | |
Standard Measuring Range: | 50 to 300 ppm / 5 to 80 ppm |
Number of Strokes n: | 2/10 |
Time for Measurement: | approx. 2 min / approx. 10 min |
Standard Deviation: | ± 10 to 15 % |
Color Change: | white --> pale brown |
Ambient Operating Conditions | |
Temperature: | 2 to 40 °C |
Absolute Humidity: | max. 20 mg H2O / L |
Reaction Principle | |
Toluene + I2O5 + H2SO4 --> I2 | |
Cross Sensitivity | |
10 ppm phenol, 1,000 ppm acetone, 1,000 ppm ethanol and 300 ppm octane are not indicated, xylene (all isomers) and benzene are indicated with the same sensitivity. The discoloration in the presence of p-xylene is violet, and yellowish-green with benzene. | |