Drager Short Term Detection Tubes - Xylene 10/a (Pack of 10)

PRODUCT CODE:
6733161

These tubes are designed for spot-measurements and must be used with the Drager Accuro Gas Detection Pump. Buy now from Frontline Safety.

Loading...
£86.48 inc VAT
£72.07

Product description

Drager Detection Tubes - Xylene 10/a (Pack of 10)

These Xylene tubes from Drager Safety have a measurement range of 10 to 400 ppm and come in a pack of 10 tubes.

These particular short-term gas detection tubes can detect other substances including p-tert-Butyltoluene, 2,5- Dimethylanisole, Napthalene and Xylene (all isomers). 

Please note this product has a shelf life of 2 years.

Short-term detection tubes require the use of the Drager Accuro Gas Detection Pump.  Click here to buy this product.

Key Features

  • Reach difficult measurement areas with the tubes, pump and accessories
  • Carry out measurements on the spot
  • Measurement results may take between 10 seconds and 15 minutes depending on the type of tube uses
  • Applications for use include variations in concentrations in the workplace, contamination of breathing zones, pre-entry checks and confined space entry
Specification
Application Range  
Standard Measuring Range: 10 to 400 ppm
Number of Strokes n: 5
Time for Measurement: approx. 1 min.
Standard Deviation: ± 20 to 30 %
Color Change: white --> red brown
   
Ambient Operating Conditions  
Temperature: 0 to 40 °C
Absolute Humidity: 3 to 15 mg H2O / L
   
Reaction Principle  
C6H4(CH3)2 + HCHO + H2SO4 --> quinoid reaction product
 
Cross Sensitivity
Styrene, vinyl acetate, toluene, ethyl benzene and acetaldehyde are indicated, but with different sensitivities.

No interference by:
500 ppm octane
200 ppm methanol
400 ppm ethyl acetate