The Drager X-am 8000 is a multi gas detector that's capable of detecting up to 7 gases. The unit can be placed in either pump or diffusion mode which makes it suitable for confined space applications.
It can house 5 sensors including LEL, IR LEL, CO2, VOC (PID), O2, CO, H2S, NO, NO2, SO2, PH3, HCN, CL2 and H2 amongst others. Using a pre-tube, the X-am 8000 can be used for benzene-specific measurements and also provides assistance for clearance measurements and leak detection.
The glowing green D-light (which is optional) can be used to indicate that the X-am has been tested and is ready for use. The pump in the X-am 8000 is very powerful and can be connected with hoses of up to 45m in length. The pump adapter will allow the use to switch between pump and diffusion mode. This provides the advantage of only needing to operate the pump when it's actually needed, thus saving energy and reducing wear and tear.
See below available configurations and click 'Read More' to expand the list:
| 8325800D-A-P-H | Drager X-am 8000 Diffusion (CatEx/H2S-LC-CO-LC/O2) |
| 8325800P-A-P-H | Drager X-am 8000 Pumped (CatEx/H2S-LC-CO-LC/O2) |
| 8325800D-A-P-H-U | Drager X-am 8000 Diffusion (CatEx/H2S-LC-CO-LC/O2/SO2) |
| 8325800P-A-P-H-U | Drager X-am 8000 Pumped (CatEx/H2S-LC-CO-LC/O2/SO2) |
| 8325800D-A-P-H-G | Drager X-am 8000 Diffusion (CatEx/H2S-LC-CO-LC/O2/PID HC) |
| 8325800P-A-P-H-G | Drager X-am 8000 Pumped (CatEx/H2S-LC-CO-LC/O2/PID HC) |
| 8325800D-A-P-H-Z | Drager X-am 8000 Diffusion (CatEx/H2S-LC-CO-LC/O2/NH3) |
| 8325800P-A-P-H-Z | Drager X-am 8000 Pumped (CatEx/H2S-LC-CO-LC/O2/NH3) |
| 8325800D-A-P-H-AA | Drager X-am 8000 Diffusion (CatEx/H2S-LC-CO-LC/O2/CO2) |
| 8325800P-A-P-H-AA | Drager X-am 8000 Pumped (CatEx/H2S-LC-CO-LC/O2/CO2) |
|
Measuring Ranges |
See Datasheet for measuring ranges and resolutions |
|
Size |
179 x 77 x 42 mm |
|
Weight |
Approx. 550g (depending on sensor configuration) with pump |
|
Temperature |
-20° C to 50° C |
|
Relative Humidity |
10 to 90% (short-term up to 95%) r.h. |
|
Pressure |
700 to 1300 hPa |
|
Energy Supply |
Lithium-ion battery, rechargeable, inductive charging |
|
Operating Times (Diffusion) |
|
|
Charging Time |
Typically 4 hours after use during a shift of max. 10 hours |
|
Start-up Times |
Typically <60 seconds for standard sensors |
|
Approvals |
|
|
Warranty |
|