Drager Short Term Detection Tubes - Phosgene 0.25/c (Pack of 10)

PRODUCT CODE:
CH28301

These tubes are designed for spot-measurements and must be used with the Drager Accuro Gas Detection Pump. Buy now from Frontline Safety.

£107.38 inc VAT
£89.48
Loading...

Product description

Drager Short Term Detection Tubes - Phosgene 0.25/c (Pack of 10)

These Drager short-term gas detection tubes are cost-effective and are used to measure Phosgene (0.25/c).  They have a measurement range of 0.25 to 25 ppm and have a shelf life of 2 years.  One pack contains 10 tubes.

 Click here to view more information on the compatible Drager Accuro Gas Detection Pump for short-term detection tubes.

Key Features

  • Obtain readings from hard to reach places with the tubes, pump and accessories
  • Carry out measurements on the spot
  • 10 seconds to 15 minutes is the potential time frame for readings to be taken and is dependent on the type of tube used
  • Pre-entry checks and confined space entry are two applications which can use tubes
  • Additional applications may include variations in concentration levels and also contamination of breathing areas 
Specification
Application Range 
Standard Measuring Range: 0.25 to 5 ppm
Number of Strokes n: 5
Time for Measurement: approx. 1 min
Standard Deviation: ± 15 to 20 %
Color Change: yellow - blue green
   
Ambient Operating Conditions 
Temperature: 5 to 35 °C
Absolute Humidity: 3 to 15 mg H2O / L
   
Reaction Principle 
COCI2 + ethylaniline +
dimethylaminobenzaldehyde - blue green reaction product
 
Cross Sensitivity
No interference by up to 100 ppm hydrochloric acid. Carbonyl bromide and acetyl chloride are indicated, but with different sensitivities. It is impossible to measure phosgene in the presence of carbonyl bromide or acetyl chloride.