Size
|
2.7 x 2.6 x 1.4 in. / 7.0 x 6.7x 3.6 cm (1-Series sensor models) `
2.7 x 2.6 x 1.6 in. / 7.0 x 6.7x 4.1 cm (4-Series sensor models)
|
|
Weight
|
3.6 to 4.1 oz. / 103 to 116 g, depending on installed sensor
|
|
Humidity
|
0% - 95% RH (non-condensing)
|
|
Typical Battery Life
|
12 months (6 months for 1-Series O2 and 4 months for 1S CO2)
|
|
User Options
|
Reset TWA, STEL and Peak readings Change High, Low, TWA and STEL alarm setpoints Latching alarms Enable IntelliFlash and non-compliance indicators Set calibration and/or bump test reminders Assign worker and location assignments Language select: English, French, Spanish, German, Italian, Russian, Japanese, Chinese, Korean, Portuguese, Dutch (Honeywell BW™ Solo Lite*: English, Russian, Japanese, Chinese and Korean only)
|
|
Approvals
|
n: Class I, Division 1, Groups A, B, C, D T4 Class I, Zone 0, AEx/Ex ia IIC T4 Ga -40°C≤ Tamb ≤ 60°C ATEX*: Sira 18ATEX2243 X 2460 g II 1G Ex ia IIC T4 Ga g I M1 Ex ia I Ma -40°C≤ Tamb ≤ 60°C IECEx: IECEx SIR 18.0058 Ex ia IIC T4 Ga / Ex ia I Ma -40°C≤ Tamb ≤ 60°C FCC ID: SU3BWS1 IC: 20969-BWS1 RED: RE-D Directive 2014/53/EU
*CO2 version currently non-ATEX. Approval pending for ATEX.
|
|
Warranty
|
3 years for 1-Series detectors and sensors (H2S, CO, O2) 2 years for 4-Series detectors and sensors (1 year for NH3, Cl2, O3, ETO, ClO2 sensors)
|
|
H2S (Hydrogen Sulphide) – 1 series (SKU: BWS-HL-Y)
|
Range – 0-200ppm Resolution – 0.1ppm Operating Temp - -40 to +140°F / -40 to +60°C
|
|
CO (Carbon Monoxide) – 1 series (SKU: BWS-ML-Y)
|
Range – 0-2000ppm Resolution – 1ppm Operating Temp - -40 to +140°F / -40 to +60°C
|
|
O2 (Oxygen) – 1 series (BWS-XL-Y)
|
Range – 0-30% v/v Resolution – 0.1ppm Operating Temp - -40 to +140°F / -40 to +60°C
|
|
CO2 (Carbon Dioxide) – 1 series** (BWS-BL-Y)
|
Range – 0 - 50,000ppm Resolution – 100ppm Operating Temp - -4 to +140°F / -20 to +60°C **Certifications Pending
|
|
Cl2 (Chlorine) – 4S (SKU: BWS-C-Y)
|
Range – 0-50ppm Resolution – 0.1ppm Operating Temp - -4 to +104°F / -20 to +30°C
|
|
ClO2 (Chlorine Dioxide) – 4S (SKU: BWS-V-Y)
|
Range – 0-1ppm Resolution – 0.01ppm Operating Temp - -4 to +104°F / -20 to +30°C
|
|
CO-H – 4S (SKU: BWS-M2-Y)
|
Range – 0-2000ppm Resolution – 0.5ppm Operating Temp - -22 to +122°F / -30 to +50°C
|
|
ETO – 4S (SKU: BWS-E-Y)
|
Range – 0-100ppm Resolution – 0.1ppm Operating Temp - -4 to +104°F / -20 to +40°C
|
|
H2 (Hydrogen) – 4S (SKU: BWS-R-Y)
|
Range – 0-1000ppm Resolution – 2ppm Operating Temp - -4 to +122°F / -20 to +50°C
|
|
H2S (Hydrogen Sulphide EXT) – 4S (SKU: BWS-H2-Y)
|
Range – 0-500ppm Resolution – 0.1ppm Operating Temp - -40 to +122°F / -40 to +50°C
|
|
HCN (Hydrogen Cyanide) 4S (SKU: BWS-Z-Y)
|
Range – 0-100ppm Resolution – 0.1ppm Operating Temp - -22 to +122°F / -30 to +50°C
|
|
NH3 (Ammonia) 4S - (SKU: BWS-A-Y)
|
Range – 0-100ppm Resolution – 1ppm Operating Temp - -4 to +104°F / -20 to +50°C
|
|
NH3-Ext (Ammonia) 4S (SKU: BWS-A2-Y)
|
Range – 0-1000ppm Resolution – 1ppm Operating Temp - -4 to +104°F / -20 to +50°C
|
|
NO (Nitric Oxide) 4S (SKU: BWS-N-Y)
|
Range – 0-250ppm Resolution – 0.2ppm Operating Temp - -22 to +122°F / -30 to +50°C
|
|
NO2 (Nitrogen Dioxide) 4S (SKU: BWS-D-Y)
|
Range – 0-100ppm Resolution – 0.1ppm Operating Temp - -4 to +122°F / -20 to +50°C
|
|
O3 (Ozone) 4S (SKU: BWS-G-Y)
|
Range – 0-1ppm Resolution – 0.01ppm Operating Temp - -22 to +122°F / -30 to +50°C
|
|
PH3 (Phosphine) 4S (SKU: BWS-P-Y)
|
Range – 0-5ppm Resolution – 0.1ppm Operating Temp - -4 to +122°F / -20 to +50°C
|
|
SO2 (Sulphur Dioxide) 4S (SKU: BWS-S-Y)
|